PAGE 40
SECTION 4:
ELECTRICAL SYSTEM
This mower is equipped with one protective fuse: a 30-
amp main fuse (pictured to the right).
A blown fuse usually indicates a problem within the
electrical system or an electrical component. Ensure the
battery terminals are tightly fastened. Never replace a
fuse with one of a higher amperage rating or ‘bypass’ a
fuse in any way. Doing so creates a significant fire hazard
and can cause severe damage to the mowers electrical
components. If a fuse is repeatedly blowing, contact your
Bad Boy dealer.
On most models, the red wire coming out of the engine is
the charging wire from the alternator. Check for 13.6 -
14.2 volts dc at this wire with engine at full throttle.
If you are having issues starting your mower ensure the
signal wire is connected to your starter solenoid.
Check the condition and connection of the relays located
under the control panel. Ensure that they are clean and
connected. Make sure that wire terminal ends have not
been pushed out of the relay block.