Cleaning Device d-800 Page 6
equipment and facility engineering
3.2 Security checks
In order to meet the requirements of the DGUV regulation 109-010, there is the necessity to check
the cleaning device for "safe working condition" before initial start-up as well as annually.
In the appendix of this operating manual, the "Safety test sheet" form is available for proof of regular
safety tests. The form in connection with the tests to be carried out may only be carried out by
qualified persons. Qualified persons are specialists who, due to their training and experience, are
technically able to assess the working condition of a work equipment. For a specific definition of a
qualified person, please refer to the definition of the operational safety ordinance BetrSichV.
3.3 Operational safety
Follow warnings and warning signs!
• Fire, open light and smoking prohibited!
• Open fires and other sources of ignition (eg grinders or welding points) are not allowed within a
radius of 5 meters around the device. This applies e.g. also for lighting and fans as well as the
associated electrical components.
• In all cases, the local safety and operating instructions are valid for the operation of the device.
Accident prevention regulations must be followed and observed.
The device may only be operated if the integrated suction device (Venturi system with
flexible exhaust hose) is connected and the evolved (solvent) fumes are safely discharged
to the outside in the free air stream in order to avoid fire, explosion and health hazards.
Should the distance to be bridged exceed the length of the supplied exhaust air hose or should local
requirements exclude the previously described exhaust air guidance, we recommend the inclusion of
a specialist company for ventilation construction to ensure the correct operation of the device.
• Compliance with workplace exposure limits (AGW) according to safety data sheets must be
documented.
• The limit values of the TA-air and their adherence must be observed.
• In the event of a fire, immediately interrupt the compressed air supply and close the cover of the
device.