background image

14 

 

mechanism under running water. Only use liquid cleaning products. All cleaning products containing 
dry powder or powder in suspension are not to be used! 

 
 

A specific devise is integrated in the cartridge unit to adjust the flow rate. To adjust the flow rate; 

1. 

Undo head assembly 

2. 

Pull off flow adjustor 

3. 

On the exposed end of the housing there are 4 cut-outs for alternative flow rates. 

4. 

Select one for increased/reduced flow. 

5. 

Replace flow adjustor with window over selected cut-out. 

6. 

Screw head assembly into the tap body and tighten fully. 

 
 

Table 5: Troubleshooting 

FAULT 

POSSIBLE CAUSE 

CHECKS 

Pilot light not igniting 

Blockage of pilot 

 
 
 
 

Adjustment of pressure from flame 

control 

Check pilot injector is not blocked 

as described in servicing 

instructions - pilot and flame 

safeguard 

 

Check gas pressure to pilot as 

described under servicing 

instruction - adjustments 

Pilot light not establishing 

 
 
 

Positioning of thermocouple 

 
 
 
 

Faulty thermocouple 

 
 

Faulty flame failure control valve 

Check connection of the 

thermocouple to the control is not 

loose 

 

Adjust positioning of thermocouple 

to ensure pilot flame is hitting 

thermocouple 

 

Contact manufacturer or 

authorized service agent 

 

Contact manufacturer or 

authorized service agent 

Pilot established, main burner not 

lighting 

Faulty thermocouple 

 

Faulty flame failure control valve 

Contact manufacturer 

 

Contact manufacturer 

Telescopic laundry arm constantly 

running (on water/deck cooled 

stock pot table) 

Warn tap washer 

 

Change washers in tap assembly 

 

Contact manufacturer or 

authorized service agent 

Wokspout constantly running 

water when in 'OFF' position 

Faulty 'O' ring in Wok spout 

Changing of 'O' ring as per service 

kit and instructions provided with 

appliance 

 

Contact manufacturer or 

authorized service agent 

Short/long laundry arm constantly 

running (when fitted with timer 

operated knee valve) 

Faulty knee valve 

 

Faulty knee valve cartridge 

Changing of knee valve cartridge 

 

Contact manufacturer or 

authorized service agent 

 
 
 

To obtain further service information concerning this appliance, please contact; 

B&S Commercial Kitchens Pty Ltd

 

57 Plateau Road 
Reservoir   VIC   3073 
Tel.: + 61 3 9469 4754 

Fax.: + 61 3 9469 4504 

E-mail: 

[email protected]

 

 

Summary of Contents for UFWWSP Series

Page 1: ...94694504 Web www bscommercialkitchens com Please ensure this booklet is kept in a safe and prominent location for future reference The reproduction on or copying of any part of this booklet via any me...

Page 2: ...D 1 5 Table 4 Plumbing Connections 6 Figure 3 Plumbing Connections VUFWWSP 1 6 Table 5 Plumbing Connections 6 IMPORTANT WARNINGS 6 Installation Instructions 7 Regulations 7 Data Label 7 Ventilation 8...

Page 3: ...aining Access to Gas and or Water System 12 Removal of Burner for Service 13 Pilot and Flame Safeguard 13 Adjustments 13 Servicing Wok Spout Where Fitted 13 Servicing Knee Valve Where Fitted 13 Gas Ty...

Page 4: ...mm x18 90 2 60 kPa Chimney Burner CB Natural Gas 0 95 mm x24 105 1 00 kPa Propane Gas 0 55 mm x24 75 2 60 kPa Please note that the minimum gas inlet pressure should be at least 1 13KPa Natural Gas an...

Page 5: ...om made appliances Height over splashback 570mm 1 300mm adjustable legs Width 1 800mm minimum with 3 stock pots Depth 840mm minimum Figure 1 Plumbing Connections UFWWSPK 1 Table 3 Plumbing Connections...

Page 6: ...5 male BSP 290 5 65 5 75 5 2 BSP 490 5 690 5 150 5 IMPORTANT WARNINGS THIS APPLIANCE SHALL ONLY BE INSTALLED SERVICED BY AN AUTHORISED INSTALLER THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH TH...

Page 7: ...e appliance if gas was not available at the time of installation As per AS NZS5601 1 clause 6 11 3 the commissioning of this appliance shall take full account of special design features the manufactur...

Page 8: ...NZS5601 1 please refer to the latest version when released The installation of the unit must comply with clauses 6 2 4 6 10 2 and 6 10 1 15 and an exhaust system shall be installed according to AS166...

Page 9: ...f the appliance An Australian certified isolating ball valve must also be fitted BEFORE CONNECTING NEW PIPE TO THIS APPLIANCE THE PIPE MUST BE BLOWN OUT THOROUGHLY TO REMOVE ALL FOREIGN MATERIAL FOREI...

Page 10: ...ls to operate correctly after all checks have been carried out please contact B S Commercial Kitchens Pty Ltd 57 Plateau Road Reservoir VIC 3073 Tel 61 3 9469 4754 Fax 61 3 9469 4504 E mail info bscom...

Page 11: ...on with Knee Valve Where Fitted The Laundry arm also serves the purpose of cleaning the appliance and or for filling a stock pot vessel with water to be used for cooking purposes Flow cycle is actuate...

Page 12: ...r authorized service agent Servicing Instructions WARNING Servicing shall be carried out by authorized personnel only Failure to do so will void the B S warranty and may result in damage to equipment...

Page 13: ...nel as described under GAINING ACCESS TO GAS CONTROL 2 To increase gas pressure to pilot turn adjustment screw located at the top right hand side of the flame failure devise anti clockwise 3 To decrea...

Page 14: ...n of the thermocouple to the control is not loose Adjust positioning of thermocouple to ensure pilot flame is hitting thermocouple Contact manufacturer or authorized service agent Contact manufacturer...

Page 15: ...been installed in accordance with local regulations by a duly authorised person and the B S installation instructions provided with the appliance If in doubt please contact B S or their representative...

Page 16: ...ty Breakage of pilot knobs knee valve handles and knee wands are not covered under warranty Thermocouples piezo leads and ignitors are only covered by twelve 12 months parts and labour across K B S Bl...

Reviews: