background image

 

Product Specifications & Introduction 

 

Appliance Name:

                            

UFWWSP Series Commercial Stock Pot Table 
This appliance may be branded as B&S, K plus and Verro 

 
We are confident that you will be delighted with your B&S stock pot, and that it will become the backbone of 
your  kitchen.      To  ensure  you  receive  the  utmost  benefit  from  your  new  B&S  appliance,  there  are 
two important things you can do. 

 

1. 

Ensure  you  read  this  booklet  carefully  and  carefully  follow  the  instructions  given.  Ensure  that  this 
booklet is kept in a safe and prominent location for future reference. 
 

2. 

Should  you  be  unsure  of any  aspect  of the  operation/performance, servicing  and  installation  of the 
appliance,  please  contact  your  B&S  dealer  immediately.    In  most  instances  a  phone  call  could 
answer your question. 

Table 1: Nominal Terminal Input Rates & Injector Sizes 

Burner Type 

Gas Type 

Injector Size 

(mm) 

MJ/h per Burner 

Test Point 

Pressure 

Duck Bill Burner 

(DB)

 

Natural Gas 

1.40 mm (x18) 

126 

1.00 kPa 

Propane Gas 

0.70 mm (x18) 

90 

2.60 kPa 

Chimney Burner 

(CB) 

Natural Gas 

0.95 mm (x24) 

105 

1.00 kPa 

Propane Gas 

0.55 mm (x24) 

75 

2.60 kPa 

Please note that the minimum gas inlet pressure should be at least 1.13KPa (Natural Gas) and 2.75KPa 
(Propane). Gas pressure must be checked when all other equipment on the same line is turned ON high. 

Manufactured By: 
Certificate Holder:

 

 

 
 
 

 

Model Number/s:

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

Approval Number: 

Gas Types:

 

B&S Commercial Kitchens Pty Ltd 
57 Plateau Road 
Reservoir   Victoria   3073 
Tel; + 61 3 9469 4754     Fax: +61 3 9469 4504 
E-mail: [email protected]

 

How to read model numbers;  
(V)UFW 

– W – D(K) – SP –1/2/3 – CB – LS – P-LR 

                                                     

 

UFW 

=

 

Unflued Table (All Models) 

 

W    

= Waterless Model 

 

Where Applicable 

 

D     

= Deluxe Model 

– Stainless Steel Chassis (where 

applicable) 

 

SP   

= Stock Pot Table 

V at the beginning indicates Verro model. 
K indicates K plus model. 

Number of stock pot holes

 

- Single Hole 

- Two Holes 

3

 - Three Holes 

Burner type/s

 

 

CB  

= Chimney Burner 

 

LS    

= Low Splashback 

 

Where Applicable 

 

P      

=

 

Plinth Mount ( only for Verro units) 

 

 CBM          = 

Cabinet base mounted 

    LR               =  Large 

17” ring(1-4)          

 

E.G.  

UFWW 

–  SP –  2 –  CB –  LS 

Is a waterless stock pot model, with two holes, two chimney burners and 
has low height splashback. 

 

GMK 10701 

Natural Gas and Propane Gas

 

Summary of Contents for UFWWSP Series

Page 1: ...94694504 Web www bscommercialkitchens com Please ensure this booklet is kept in a safe and prominent location for future reference The reproduction on or copying of any part of this booklet via any me...

Page 2: ...D 1 5 Table 4 Plumbing Connections 6 Figure 3 Plumbing Connections VUFWWSP 1 6 Table 5 Plumbing Connections 6 IMPORTANT WARNINGS 6 Installation Instructions 7 Regulations 7 Data Label 7 Ventilation 8...

Page 3: ...aining Access to Gas and or Water System 12 Removal of Burner for Service 13 Pilot and Flame Safeguard 13 Adjustments 13 Servicing Wok Spout Where Fitted 13 Servicing Knee Valve Where Fitted 13 Gas Ty...

Page 4: ...mm x18 90 2 60 kPa Chimney Burner CB Natural Gas 0 95 mm x24 105 1 00 kPa Propane Gas 0 55 mm x24 75 2 60 kPa Please note that the minimum gas inlet pressure should be at least 1 13KPa Natural Gas an...

Page 5: ...om made appliances Height over splashback 570mm 1 300mm adjustable legs Width 1 800mm minimum with 3 stock pots Depth 840mm minimum Figure 1 Plumbing Connections UFWWSPK 1 Table 3 Plumbing Connections...

Page 6: ...5 male BSP 290 5 65 5 75 5 2 BSP 490 5 690 5 150 5 IMPORTANT WARNINGS THIS APPLIANCE SHALL ONLY BE INSTALLED SERVICED BY AN AUTHORISED INSTALLER THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH TH...

Page 7: ...e appliance if gas was not available at the time of installation As per AS NZS5601 1 clause 6 11 3 the commissioning of this appliance shall take full account of special design features the manufactur...

Page 8: ...NZS5601 1 please refer to the latest version when released The installation of the unit must comply with clauses 6 2 4 6 10 2 and 6 10 1 15 and an exhaust system shall be installed according to AS166...

Page 9: ...f the appliance An Australian certified isolating ball valve must also be fitted BEFORE CONNECTING NEW PIPE TO THIS APPLIANCE THE PIPE MUST BE BLOWN OUT THOROUGHLY TO REMOVE ALL FOREIGN MATERIAL FOREI...

Page 10: ...ls to operate correctly after all checks have been carried out please contact B S Commercial Kitchens Pty Ltd 57 Plateau Road Reservoir VIC 3073 Tel 61 3 9469 4754 Fax 61 3 9469 4504 E mail info bscom...

Page 11: ...on with Knee Valve Where Fitted The Laundry arm also serves the purpose of cleaning the appliance and or for filling a stock pot vessel with water to be used for cooking purposes Flow cycle is actuate...

Page 12: ...r authorized service agent Servicing Instructions WARNING Servicing shall be carried out by authorized personnel only Failure to do so will void the B S warranty and may result in damage to equipment...

Page 13: ...nel as described under GAINING ACCESS TO GAS CONTROL 2 To increase gas pressure to pilot turn adjustment screw located at the top right hand side of the flame failure devise anti clockwise 3 To decrea...

Page 14: ...n of the thermocouple to the control is not loose Adjust positioning of thermocouple to ensure pilot flame is hitting thermocouple Contact manufacturer or authorized service agent Contact manufacturer...

Page 15: ...been installed in accordance with local regulations by a duly authorised person and the B S installation instructions provided with the appliance If in doubt please contact B S or their representative...

Page 16: ...ty Breakage of pilot knobs knee valve handles and knee wands are not covered under warranty Thermocouples piezo leads and ignitors are only covered by twelve 12 months parts and labour across K B S Bl...

Reviews: