10
pilot burner knob anti-clockwise to
“ON”.
B.
Light pilot manually.
C.
Continue to hold in the flame safe guard button for about 25 to 30 seconds.
D.
Observe whether the pilot is alight.
E.
If not repeat steps
A.
to
D.
F.
If it is alight turn main burner valve anti-clockwise to the
“ON” positions
G.
Check that burner is properly alight.
Chimney Burners
– Pilot Light Chimney Burner
A.
Ensure pilot light head is located no further than 45mm from the injector located opposite the
burner inlet.
In the event the appliance fails to operate correctly, check the following;
1. Data plate to ensure correct gas type and pressure (adjust if necessary)
2. Adjust aeration by adjusting air shutter located at the front of the venture of the main burner.
3. Injector sizes
– check against data plate and installation manual
4. View pilot size and adjust if required.
In case appliance fails to operate correctly after all checks have been carried out, please contact;
B&S Commercial Kitchens Pty Ltd
57 Plateau Road
Reservoir VIC 3073
Tel.: + 61 3 9469 4754 Fax.: + 61 3 9469 4504 E-mail: [email protected]
Operating Instructions
WARNING
•
DO NOT
spray aerosols in the vicinity of this appliance while it is in operation.
•
DO NOT
store or use flammable liquids or items in the vicinity of this appliance.
•
Prior to lighting, smell area surrounding the appliance for gas (please note that as
some gas types are heavier than air, we recommended the operator to also smell
the floor around the appliance).
•
In the event you smell gas:
DO NOT
light any appliance.
DO NOT
touch/ operate
any electrical switch or phone in your building. Call local gas supplier
immediately
and follow their instructions.
IMPORTANT WARNING!
ENSURE NO OR MINIMAL AMOUNTS OF OIL AND FOODSTUFFS FALL INTO THE BURNER AREA
WHILST COOKING. FAILURE TO DO SO MAY AFFECT THE EFFICIENT AND SAFE OPERATION ON
THE APPLIANCE AND
MAY VOID WARRANTY
Laundry arm
Splashback
Trivet
Hob
Gas controls