User Manual  v1.1

RFM-LR1

Index

Description

Datatype

Encoding

Valid range

Access

Unsolicited

Description

Note

0x03

FW build hash

6 x Uint8

Query

No

Unique number that identifies the firmware version

0x05

Device reset

Action

No

Reset of device 

0x06

CPU voltage

Uint8

25mV/ 

LSB 

0 - 3.6V

Query

No

Read CPU voltage. 

Max/min ranges depend on battery chemistry.

0x0A

CPU temperature

Uint16 

Big endian 

0.01C / 

LSB 

-50 - +125 C

Query

No

Temperature from CPU sensor with 50 °C offset. 

Approximately 5 °C accuracy.

0x20

Status

Uint8

Bitfield

Set 

Query 

Yes 

Bit 7: Flow exceeds Q3 at least for 10 min  

Bit 6: - 

Bit 5: Magnetic fraud attempt  

Bit 4: - 

Bit 3: Module removed  

Bit 2: - 

Bit 1: - 

Bit 0: Leakage during last 24 hours 

To clear alarms: 

0xFF clears no alarms, 

0x00 clears all alarms,

0x80 clears all alarms except 

‘module removed’ etc.

0x21

Volume

Uint32 

Big endian 

Liter

Query

Yes 

Volume as indicated on meter x 0.001 m3 

0x22

Reporting interval Uint16 

Big endian 

Minutes

1-10080

Set 

Query 

No

Reporting interval in minutes

0x25

Starting value

Uint32 

Big endian 

Liter

Set 

Query 

No

Volume as indicated on meter 

x 0.001 m3 

0x27

Back flow volume

Uint32 

Big endian 

Liter

Query

No

Volume as indicated on meter 

x 0.001 m3 

0x2B

Q3MaxFlow

Uint16 

Big endian 

Liters per hour

0 - 65535

Set 

Query 

No

Corresponds to mechanical meter Q3 (based on pipe)

0x2C

Leak Window size

Uint8

Number of 15 

seconds samples 1 - 255

Set 

Query 

No

The size, in units of 15 seconds sample windows, in 

which we expect flow below “zero tolerance” to reset 

leak detection

0x2D

Leak Zero tolerance UInt8

Opto phase 

changes

0 - 255

Set 

Query 

No

Zero tolerance, max number of shaft phase changes 

considered “not moving”.

Summary of Contents for RFM-LR1

Page 1: ...deactivated The device activates when the red button is pressed for more than 8 seconds This happens automatically when the unit is mounted on to a GSD8 RFM mechanical water meter The following safety...

Page 2: ...essages are received The device tries to re join the network if it has not heard anything from the network for 288 uplinks 36 days Startup Sequence When the device has joined the network startup trans...

Page 3: ...al Physical installation process 1 Mount RFM LR1 unit on the water meter 2 Mount the locking pin and seal If you require further support please contact support bmeters com or your vendor Activating on...

Page 4: ...n this alarm flag is set Magnetic fraud attempt The module has a detector that can sense if a magnet is used to manipulate the function of a dry dial water meter If a magnet is sensed the alarm flag i...

Page 5: ...re key storage Battery life Battery life length 10 years at 4 hour intervals at SF12 Primary cell Lithium Manganese 3V Capacity 2 2 Ah Method Optical readout Using infrared diodes Weight Weight 85 g C...

Page 6: ...mands to be sent After approximately 2 minutes the device changes to Operational state Port Port 1 Payload 0x01 20 00 0x01 Data type 0x20 Status command 0x00 bit0 0 Normal startup bit1 0 No boot probl...

Page 7: ...o alarms 0x00 clears all alarms 0x80 clears all alarms except module removed etc 0x21 Volume Uint32 Big endian Liter Query Yes Volume as indicated on meter x 0 001 m3 0x22 Reporting interval Uint16 Bi...

Page 8: ...ting Module removed alarm flag Downlink 012000 Uplink 012000 Resets all alarm flags Downlink 012205A0 Uplink 012205A0 Sets the Reporting interval to 1440 minutes 24 hours Downlink 0227 Uplink 01270000...

Page 9: ...on slots parameters 0x05 RXParamSetupAns End device Acknowledges a RXSetupReq command 0x06 DevStatusReq Gateway Requests the status of the end device 0x06 DevStatusAns End device Returns the status of...

Reviews: