There are at least five startup transmissions. The Status command (index 0x20) is sent unless a reply to a 

downlink is sent. If no replies are sent the Status commands are sent with increasing intervals starting with 

15 seconds and ending with two minutes. This startup sequence should be utilized to set the starting value of 

the water meter (if not equal to 0 m

3

). For accurate calibration, the water meter should not be used during the 

calibration.

Physical installation

When the meter has been digitally configured into your Lora network it is time to physically activate and install 

it. The installer mounts the RFM-LR1 unit on the GSD8-RFM and mount the locking pin and seal. 

 

Physical installation process

1.

 Mount RFM-LR1 unit on the water meter

2. 

Mount the locking pin and seal

If you require further support, please contact [email protected] or your vendor.

Activating on the network

Standard devices are configured to use OTAA (Over The Air Activation). It is possible to order a batch of devices 

configured for ABP (Activation By Personalization). 

 

Standard devices are configured with the AppEUI (a.k.a. JoinEUI) 70-B3-D5-D7-2F-F8-1301. It is possible to 

order a batch of devices configured with a customer unique AppEUI for this contact B METERS support. 

 

Upon receiving your RFM-LR1 you can request from B METERS the necessary information to connect it to your 

network server. This consists of the following: 

1. DevEUI 

2. AppKey 

These codes are unique for each device. The DevEUI can be seen as a unique identification code, the AppKey is 

a securely generated authentication code.  

Summary of Contents for RFM-LR1

Page 1: ...deactivated The device activates when the red button is pressed for more than 8 seconds This happens automatically when the unit is mounted on to a GSD8 RFM mechanical water meter The following safety...

Page 2: ...essages are received The device tries to re join the network if it has not heard anything from the network for 288 uplinks 36 days Startup Sequence When the device has joined the network startup trans...

Page 3: ...al Physical installation process 1 Mount RFM LR1 unit on the water meter 2 Mount the locking pin and seal If you require further support please contact support bmeters com or your vendor Activating on...

Page 4: ...n this alarm flag is set Magnetic fraud attempt The module has a detector that can sense if a magnet is used to manipulate the function of a dry dial water meter If a magnet is sensed the alarm flag i...

Page 5: ...re key storage Battery life Battery life length 10 years at 4 hour intervals at SF12 Primary cell Lithium Manganese 3V Capacity 2 2 Ah Method Optical readout Using infrared diodes Weight Weight 85 g C...

Page 6: ...mands to be sent After approximately 2 minutes the device changes to Operational state Port Port 1 Payload 0x01 20 00 0x01 Data type 0x20 Status command 0x00 bit0 0 Normal startup bit1 0 No boot probl...

Page 7: ...o alarms 0x00 clears all alarms 0x80 clears all alarms except module removed etc 0x21 Volume Uint32 Big endian Liter Query Yes Volume as indicated on meter x 0 001 m3 0x22 Reporting interval Uint16 Bi...

Page 8: ...ting Module removed alarm flag Downlink 012000 Uplink 012000 Resets all alarm flags Downlink 012205A0 Uplink 012205A0 Sets the Reporting interval to 1440 minutes 24 hours Downlink 0227 Uplink 01270000...

Page 9: ...on slots parameters 0x05 RXParamSetupAns End device Acknowledges a RXSetupReq command 0x06 DevStatusReq Gateway Requests the status of the end device 0x06 DevStatusAns End device Returns the status of...

Reviews: