ESD5500E Series Speed Control Unit 2-2021-F2  PIB1002

ESD5500E Series

Speed Control Unit

1

2

INTRODUCTION

SPECIFICATIONS

Performance

Isochronous Operation

± 0.25 % or better

Speed Range / Governor

1 - 7.5 kHz Continuous

Speed Drift with Temperature

±1 % MAX

Idle Adjust Clockwise

60 % of Set Speed

Idle Adjust Counterclockwise

Less than 1200 Hz

Droop Range

1 - 5 % regulation

Droop Adjust Maximum

(K-L jumpered)

400 Hz ±75 Hz per 1.0 A change

Droop Adjust Minimum

(K-L jumpered)

15 Hz ±75 Hz per 1.0 A change

Speed Trim Range

± 200 Hz

Remote Variable Speed 

Range

500 - 7.5 kHz

Terminal Sensitivity

           J

           L

           N

           P

100 Hz ±15 Hz/Volt @ 5.0 kΩ Impedance

735 Hz ±60 Hz/Volt @ 65.0 kΩ Impedance

148 Hz ±10 Hz/Volt @ 1 MΩ Impedance

10 V DC Supply @ 20 mA MAX

InPut / outPut

DC Supply

12 V DC and 24 V DC Battery Systems 

Transient and Reverse Voltage Protected*

Polarity

Negative Ground (Case Isolated)

Power Consumption

50 mA continuous plus actuator current

Speed Signal Range

Speed Sensor Signal

1.0 - 50 V AC

1.0 - 120 V RMS

Actuator Current Range**

(77°F (25°C))

Minimum 1.0 A

Nominal   7.0 A

Peak 10.0 A

The ESD5500E Series Speed Control Unit is an all-electronic device designed to control 

engine speed quickly and precisely in response to transient load changes.  

The ESD5500E controls a wide variety of engines in isochronous or droop mode when 

connected to a proportional electric actuator and magnetic speed sensor. The ruggedly 

built ESD5500E series is designed to withstand the engine environment. Light-Force 

variations are available.

moDeL

DeScrIPtIon

ESD5500E

Multi-VDC / Standard Unit 

ESD5520E

Multi-VDC / Light-Force (Low-Current Optimized PID) / Enhanced Droop

ESD5522E

Multi-VDC / Light-Force (Low-Current Optimized PID) / Enhanced Droop 

for Cummins EFC Forward Acting (Normally Closed)

ESD5526E

Multi-VDC / Light-Force (Low-Current Optimized PID) / Anti-Windup 

Circuit (Gaseous) / Recommended for T1/T2 ATBs

ESD5528E

Multi-VDC / Anti-Windup Circuit (Gaseous) / Recommended for T3/T4 

ATBs

reLIaBILItY

Vibration

1 g @ 20-100 Hz

Testing

100 % Functionally Tested

envIronmentaL

Ambient Temperature

-40° to 85 °C [-40° to 180 °F]

Relative Humidity

up to 95 %

All Surface Finishes

Fungus Proof, Corrosion Resistant

comPLIance / StanDarDS

Agency

CE (EN55011, EN50081-2, EN50082-2), 

RoHS, Lloyds Register, 

DNV/GL, Bureau Veritas 

PHYSIcaL

Dimension

See Wiring Diagram and Outline

Weight

1.20 lbf [0.54 kgf]

Mounting

Any position, vertical preferred

* Protected against short circuit to actuator (shuts off current to actuator), unit automatically turns on when short is removed. 

** Protected against reverse voltage by a series diode. A 15 A fuse must be installed in the positive battery lead. 

Summary of Contents for ESD5522E

Page 1: ...precisely in response to transient load changes The ESD5500E controls a wide variety of engines in isochronous or droop mode when connected to a proportional electric actuator and magnetic speed senso...

Page 2: ...trol Unit 2 2021 F2 PIB1002 Mount in a cabinet engine enclosure or sealed metal box Vertical orientation allows fluids to drain in moist environ ments Dimensions Avoid Extreme Heat 3 Installation Outl...

Page 3: ...5 Magnetic speed sensors Terminals C and D must be twisted and or shielded for the entire length 6 The gap between the speed sensor and the ring gear teeth should be smaller than 0 02 in 0 5 mm usual...

Page 4: ...tion STARTING FUEL Full CW MAX fuel SPEED RAMPING Full CCW fastest The governed speed set point is increased by clockwise rotation of the SPEED adjustment control Remote speed adjustment can be obtain...

Page 5: ...on for the ESD5500E may be selected Operating Speed or Idle METHOD 1 Operating Speed PROCEDURE Start the engine and accelerate directly to the operating speed Gen erator Sets etc METHOD 2 IDLE SPEED 1...

Page 6: ...position is OFF Use the ON position if you experience fast erratic engine behavior between the engine and generator due to a soft coupling LEA DROOP IDLE SPEED C1 OFF ON LEAD CIRCUIT OFF ON C2 SOFT C...

Page 7: ...ide range of droop is available with the internal control droop level requirements of 10 are unusual If droop levels experienced are higher or lower than those required contact GAC for assistance NOTE...

Page 8: ...e possibility of missed or extra pulses The speed control unit will govern well with 1 0 V RMS speed sensor signal A speed sensor signal of 3 V AC or greater at governed speed is recommended Measureme...

Page 9: ...V DC then check for actuator binding linkage binding If the voltage reading is below 0 8 V DC Defective speed control unit Actuator does not energize fully 1 Measure the voltage at the battery while...

Reviews: