background image

RELEASE DATE

4-10-17

REFERENCE

 

NUMBER

INS-2145-00

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

THIS DOCUMENT CONTAINS PROPRIETARY INFORMATION OF B-K LIGHTING, INC. AND ITS RECEIPT OR POSSESSION DOES NOT CONVEY ANY RIGHTS TO REPRODUCE, DISCLOSE ITS CONTENTS, OR TO MANUFACTURE, USE OR SELL ANYTHING IT MAY 

DESCRIBE.  REPRODUCTION, DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B-K LIGHTING, INC. IS STRICTLY FORBIDDEN.

3/16” Allen Wrench
Phillips Screwdriver
Level
Hammer
Waterproof Wire Nuts

Warning

High Voltage

Hot Surface

NEEDED

FOR 

INSTALLATION:

By Others

Junction Box

Power  Supply  

Compartment

Rebar Saddles 

Exterior

Patented HydroLock® 

Plate w/ Silicone

O-Ring

Interior

Patented HydroLock® 

Plate w/ Silicone

O-Ring (not shown)

Stability Flange

Adjustment Posts

Tenaya2® and its features are covered in whole or in part by U.S. Patent No. 7,175,297; U.S. Patent No. 7,033,038; 

U.S. Patent No. 6,254,258 B1; U.S. Patent No. 7,553,042;  and U.S. Patent No.  7,560,148.

TENAYA2® SERIES 

Housing Installation

Proper soil preparation is recommended before installation. See the DIG-IT guide at www.bklighting.com/dig-it for more information.

• 

Product must be installed by a qualified person in a manner 

consistent with its intended use and in compliance with the 

National Electrical Code, Canadian Electrical Code, and all Local 

and Provincial Codes. 

• 

Follow product label information and instructions.

• 

Qualified Personnel must perform all servicing or relamping of 

this product.

• 

Before wiring to power supply and during servicing or relamping, 

turn off power at fuse or circuit breaker before service.

• 

The use of accessory equipment not recommended by the 

manufacturer or installed contrary to instructions may cause an 

unsafe condition. The use of damaged components may cause 

an unsafe condition and void product warranty.

IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE ALL SAFETY 

AND INSTALLATION INSTRUCTIONS

• 

Do not block light emanating from product in whole or part, 

as this may cause an unsafe condition.

• 

Never operate the fixture with missing or damaged lens.  

Lens must be cleaned on regular basis.

• 

Entire fixture may become extremely hot. Do not touch hot 

lens or fixture body. Do not touch the lamp at any time. Use 

a clean, dry, soft cloth to handle the lamp. Oil from skin may 

damage the lamp and cause it to rupture.

• 

Replace lamp only with correct wattage and type of lamp 

marked on fixture label.

• 

All gaskets, o-rings and sealing surfaces must be kept clean 

during installation and service; failure to do this may cause an 

unsafe condition and void product warranty. 

INSTRUCTIONS PERTAINING TO 

A RISK OF FIRE, OR INJURY TO 

PERSONS IMPORTANT SAFETY 

INSTRUCTIONS

Lighted lamp is HOT!

WARNING - To reduce the risk of FIRE OR INJURY TO PERSONS:  

Turn off/unplug and allow to cool before replacing lamp.  

Lamp gets HOT quickly! Contact only switch/plug when 

turning on.  

Do not touch hot lens, guard, or enclosure (see diagram/

picture).  

Keep lamp away from materials that may burn.  

Do no touch the lamp at any time. Use a soft cloth. Oil 

from skin may damage lamp.  

Do not operate the luminaire fitting with a missing or 

damaged shield.  

 

SAVE THESE INSTRUCTIONS

 

·  Suitable for wet locations ·  Suitable for recessed in ground locations

IMPORTANT LISTINGS AND CERTIFICATIONS

IMPORTANT SAFETY INFORMATION - READ, FOLLOW, AND SAVE THESE INSTALLATION INSTRUCTIONS

Temporary Cover

Summary of Contents for Tenaya 2 Series

Page 1: ...rn off power at fuse or circuit breaker before service The use of accessory equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition The use of damaged components may cause an unsafe condition and void product warranty IMPORTANT SAFETY INFORMATION READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS Do not block light emanating from...

Page 2: ...ve sufficient clearance to elevate housing to finished grade Top of yellow temporary cover level to finished grade 4 Raise housing on EMT to finished grade top of yellow temp cover Use bubble level on yellow temporary cover to aid in leveling housing 5 When top of yellow temporary cover is level with finished grade tighten screws on Stability Flange to secure housing to EMT Remove excess EMT as ne...

Page 3: ...be level with the top of the Yellow Installation Cover Soil installation is NOT Drive over rated Concrete Drive over Soil 7 Per DIG IT Guide backfill the gap between the bottom of housing and bottom of hole with sand for drainage 8 Rotate patented HydroLock plate counter clockwise to allow notch in HydroLock plate to clear pins on junction box Pull to remove 9 Pull branch circuit wiring and extern...

Page 4: ...Concrete Product must be installed by a qualified person in a manner consistent with its intended use and in compliance with the National Electrical Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product Before wiring to power sup...

Page 5: ...he optical chamber horizontally 360 rotate the optical chamber to desired direction 8 For Optional Internal Cutoff Place internal cutoff louver in the top of the optical chamber in the desired direction of cutoff and install faceplate as normal Optional Internal Cutoff 7 Before Installation of faceplate clean solid silicone faceplate gasket see arrows and collar of debris for a proper seal FAILURE...

Page 6: ...n to 25 in lbs 5 Remove optic holder by loosening two 2 4 40 screws using a 0 05 Allen wrench 6 Carefully remove LED module from heatsink Do not pull on connector or wiring Handle with care Fragile Do not pull on connector or wiring Handle with care 7 Use small pick tool to push connector off LED board through two small slots behind connector Once loose lift connector upwards and off board 8 Place...

Page 7: ...Tighten 2 6 32 set screws to secure accessory bracket to OptiLock as shown 15 Before Installation of faceplate clean solid silicone faceplate gasket see arrows and collar of debris for a proper seal FAILURE TO DO THIS STEP WILL CAUSE FIXTURE TO FAIL AND VOID PRODUCT WARRANTY 13 If your Tenaya2 comes with optional accessory holder see Relamping with Accessory Holder to remove and install source To ...

Page 8: ...RUCTIONS 3 Insert up to 2 accessories into the accessory holder Accessories should rest on lip of accessory holder NOTE 1 Insert any accessory lens with the smooth side toward the LED 2 If using a honeycomb baffle position it farthest from the LED Accessory Replacement 4 Place accessory holder onto tabs on accessory bracket over optic 1 Pull accessory holder from accessory bracket 2 Optic should r...

Page 9: ...ighten two set screws 2 Install the faceplate using 3 16 Allen wrench and torque the faceplate screws in a cross pattern to 25 in lbs Rock Guard w Optical Opening Rock Guard Half Dome Glare Shield 1 Before installation of faceplate clean solid silicone faceplate gasket see arrows and collar of debris for a proper seal FAILURE TO DO THIS STEP WILL CAUSE FIXTURE TO FAIL AND VOID PRODUCT WARRANTY Fac...