![background image](http://html1.mh-extra.com/html/b-k-lighting/precision-2-co2-series/precision-2-co2-series_installation-instructions_3111965003.webp)
RELEASE DATE
10-21-2019
REFERENCE
NUMBER
INS001399.1
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
Installation
CO
2
SERIES
Inspiration Control System
Installation Instructions
iOS device (Not Included) with installed B-K Lighting Inspiration Application required for use.
8. Per DIG-IT Guide, backfill the gap between the
bottom of housing and bottom of hole with
sand for drainage.
9.
For soil installation:
Fill and tamp soil to
the appropriate height leaving room for sod,
pavers, etc. to be level with the top of the
temporary cover.
Soil installation is not drive-over rated.
10.
For concrete installation:
Fill the hole around
the fixture housing to 12” below the finished
grade with clean fill dirt and tamp carefully to
prevent settling of fixture. Pour concrete and
finish as required flush with the top surface of
the temporary cover.
1. Remove temporary cover.
2. Make watertight connections using waterproof
wire connectors (provided) to leads on the
bottom of Patented HydroLock® Barrier Plate
Assembly.
See wiring diagram.
Number of connections may vary depending
on wiring controls chosen as per lighting
plan. See wiring diagram.
WIRING DIAGRAM - Wireless Bluetooth® Controls
with Inspiration Application on iOS device
iOS device controls dimming, CCT, Saturation,
and Hue using Bluetooth® wireless controls and
the application.
iOS device (iPad, iPod, iPhone) with installed
B-K Lighting Inspiration application is
required.
WIRING DIAGRAM - Hybrid
Secondary wiring from remote driver connects
to fixture leads. 0-10V dimming connects to
module. 0-10V Continuous CCT connects to
module. iOS device controls Saturation and Hue.
iOS device (iPad, iPod, iPhone) with installed
B-K Lighting Inspiration application is
required.
WIRING DIAGRAM - 0-10V Wired
Secondary wiring from remote driver connects
to fixture leads. 0-10V dimming connects to
module. 0-10V Continuous CCT connects to
module and controls CCT.
iOS device (iPad, iPod, iPhone) with installed
B-K Lighting Inspiration application is
required.
Hydro
lock P
late
Line (Black)
Neut (White)
Ground (Green)
iOS
Bluetooth®
0-10V DIM + (Green)
0-10V DIM - (Black)
0-10V CCT + (Blue)
0-10V CCT - (White)
Hydro
lock Pla
te
Line (Black)
Neut (White)
Ground (Green)
0-10V DIM + (Green)
0-10V DIM - (Black)
0-10V CCT + (Blue)
0-10V CCT - (White)
Lutron E2 +(ORANGE)
Hydro
lock Pla
te
Lutron E1 - (WHITE)
Line Black
Neut White
Ground Green
WIRING DIAGRAM - Lutron
Wire Gauge Maximum & EcoSystem-Compliant
Loop Wire Length.
4.0 mm2 (12 AWG) 671 m (2200 FT)
2.5 mm2 (14 AWG) 427 m (1400 FT)
1.5 mm2 (16 AWG) 275 m (900 FT)
1.0 mm2 (18 AWG) 175 m (570 FT)
Maximum of 32 devices per loop.
Hydro
lock P
late
Line (Black)
Neut (White)
Ground (Green)
iOS
Bluetooth®