7. Attach tether wire under screw head at the base
of the UPM housing and tighten. Slowly lower
the faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM
is designed as an installation aid and NOT a
safety cable. Do not add weight to, or drop
faceplate.
REVISION DATE
12-13-11
REFERENCE
NUMBER
INS000795.8
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
Ground
Hot
Neutral
LAMP
BLUE
WHITE
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
DRIVER
6. If UPM housing is not level, remove UPM housing;
loosen but
DO NOT REMOVE
(2) #8-32 screws
with 9/64” allen wrench on CamLock™ assembly.
Adjust CamLock™ assembly up to 30° as needed
to level. Tighten the screws and reattach UPM
housing.
8. Use wire connectors (By Others) to connect driver
primary leads to branch circuit wires. Connect
incoming ground and driver ground to ground
wire provided in UPM housing. See wiring
diagram.
10. Make sure UPM housing gasket is free of any dirt
or debris. Attach the faceplate by tightening the
(4) #6-32 captive screws evenly to 6-9 in/lbs using
a 5/64” allen wrench.
A
B
C
1. Install standard 4.5” x 2.85” recessed junction box
(by others) in the final fixture location according
to designed lighting plan.
NOTE: Vertical or horizontal installation of
recessed junction box determines orientation
of UPM.
2.
Pull branch circuit wiring necessary for installation
(By Others.)
3. Feed branch circuit wiring and lamp leads to
remote mounted fixture through mounting plate
with CamLock™ assembly. Attach mounting plate
with supplied (2) #6-32 stainless steel hex drive
fasteners to recessed junction box using a 5/64”
allen wrench.
4. Feed wire into UPM housing. Install housing
on CamLock™ at 90° to finished orientation as
shown. (Figure A)
5. Rotate housing 90° counter-clockwise (Figure
B). Tighten set screw with 5/64” allen wrench
on outside of UPM housing to lock in place.
(Figure C)
Wiring Diagram.
9. Pull lamp leads into UPM housing and connect
to driver secondary leads using approved wire
connectors (By Others).
NOTE: See driver warning on page 1. Failure
to comply with wiring requirements will void
warranty.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
ETL LISTED
CONFORMS TO ANSI/UL
STANDARD 1598
CERTIFIED TO CAN/CSA
STANDARD C22.2 NO. 250
PM2RM RECTANGULAR CAMLOCK™ Driver Housing
Constant Current Driver