![B-K lighting PM2RM Installation Manual Download Page 4](http://html.mh-extra.com/html/b-k-lighting/pm2rm/pm2rm_installation-manual_3091701004.webp)
REVISION DATE
12-13-11
REFERENCE
NUMBER
INS000795.7
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
Ground
Hot
Neutral
A
B
5. Feed branch circuit wiring into UPM housing.
Install housing on CamLock™ at 90° to finished
orientation as shown. (Figure A)
6. Rotate housing 90° counter-clockwise (Figure
B). Tighten set screw with 5/64” allen wrench
on outside of UPM housing to lock in place.
(Figure C)
7. If UPM housing is not level, remove UPM housing;
loosen but
DO NOT REMOVE
(2) #8-32 screws
with 9/64” allen wrench on CamLock™ assembly.
Adjust CamLock™ assembly up to 30° as needed
to level. Tighten the screws and reattach UPM
housing.
9. Use wire connectors (By Others) to connect driver
primary leads to branch circuit wires. Connect
incoming ground and driver ground to ground
wire provided in UPM housing. See wiring
diagram.
11. Make sure UPM housing gasket is free of any
dirt or debris. Attach the faceplate by tightening
the (4) #6-32 captive screws evenly to 6-9 in/lbs
using a 5/64” allen wrench.
LAMP
BLUE
WHITE
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
DRIVER
Wiring Diagram.
10. Pull lamp leads into UPM housing and connect
to driver secondary leads using approved wire
connectors (By Others).
NOTE: See driver warning on page 1. Failure
to comply with wiring requirements will void
warranty.
8. Attach tether wire under screw head at the base
of the UPM housing. Slowly lower the faceplate
until tether is taut.
NOTE: Faceplate tether supplied with UPM
is designed as an installation aid and NOT a
safety cable. Do not add weight to, or drop
faceplate.
4. Feed branch circuit wiring and lamp leads to
remote mounted fixture through mounting
plate with CamLock™ assembly. Attach
mounting plate with supplied (2) #10-24
stainless steel hex drive fasteners to universal
ring using 1/8” allen wrench.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
ETL LISTED
CONFORMS TO ANSI/UL
STANDARD 1598
CERTIFIED TO CAN/CSA
STANDARD C22.2 NO. 250
1. Install standard 4” octagonal/round recessed
junction box in the final fixture location according
to designed lighting plan.
2.
Pull branch circuit wiring necessary for installation
(By Others.)
3. Install universal mounting ring.
IMPORTANT! Orientation of universal ring
will affect orientation of UPM! Take note of
mounting plate holes (indicated with arrows)
on the universal ring holes to mount UPM in
correct orientation.
PM2RM ROUND CAMLOCK™ Driver Housing
Constant Current Driver
Horizontal
Vertical