B-K LIGHTING

Ground

Hot

Neutral

A

B

5.  Feed branch circuit wiring into UPM housing. 

Install housing on CamLock™ at 90° to finished 
orientation as shown. (Figure A)

6.  Rotate housing 90° counter-clockwise (Figure 

B). Tighten set screw with 5/64” allen wrench 
on outside of UPM housing to lock in place. 
(Figure C)

7.  If UPM housing is not level, remove UPM housing; 

loosen but 

DO NOT REMOVE 

(2) #8-32 screws 

with 9/64” allen wrench on CamLock™ assembly. 
Adjust CamLock™ assembly up to 30° as needed 
to level. Tighten the screws and reattach UPM 
housing. 

9.  Use wire connectors (By Others) to connect driver 

primary leads to branch circuit wires. Connect 
incoming ground and driver ground to ground 
wire provided in UPM housing. See wiring 
diagram.

11.  Make sure UPM housing  gasket is free of any 

dirt or debris. Attach the faceplate by tightening 
the (4) #6-32 captive screws evenly to 6-9 in/lbs 
using a 5/64” allen wrench.

LAMP

BLUE

WHITE

QUICK DISCONNECT

LINE (BLACK)

NEUTRAL (WHITE)

GROUND (GREEN)

BARE WIRE

IN UPM

RED

BLACK

BLUE

WHITE

GREEN

DRIVER

Wiring Diagram.

10.  Pull lamp leads into UPM housing and connect 

to driver secondary leads using approved wire 
connectors (By Others). 

NOTE: See driver warning on page 1. Failure 

to comply with wiring requirements will void 
warranty.

8.  Attach tether wire under screw head at the base 

of the UPM housing. Slowly lower the faceplate 
until tether is taut. 

NOTE: Faceplate tether supplied with UPM 

is designed as an installation aid and NOT a 
safety cable. Do not add weight to, or drop 
faceplate.

4.  Feed branch circuit wiring and lamp leads to 

remote mounted fixture through mounting 
plate with CamLock™ assembly. Attach 
mounting plate with supplied (2) #10-24 
stainless steel hex drive fasteners to universal 
ring using 1/8” allen wrench.

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

ETL LISTED

 CONFORMS TO ANSI/UL

STANDARD 1598

CERTIFIED TO CAN/CSA

STANDARD C22.2 NO. 250

1.  Install standard 4” octagonal/round recessed 

junction box in the final fixture location  according 
to designed lighting plan.

2. 

Pull branch circuit wiring necessary for installation 
(By Others.)

3.  Install universal mounting ring.

 

IMPORTANT! Orientation of universal ring 
will affect orientation of UPM! Take note of 
mounting plate holes (indicated with arrows) 
on the universal ring holes to mount UPM in 
correct orientation.

PM2RM ROUND CAMLOCK™ Driver Housing

Constant Current Driver

Horizontal

Vertical

Summary of Contents for PM2RM

Page 1: ...from product in whole or part as this may cause an unsafe condition Never operate the fixture with missing or damaged lens Lens must be cleaned on regular basis Entire fixture may become extremely hot...

Page 2: ...ntain warranty Wiring Diagram 8 Pull lamp leads into UPM housing and connect to driver secondary leads using approved wire connectors By Others NOTE See driver warning on page 1 Failure to comply with...

Page 3: ...TY AND INSTALLATION INSTRUCTIONS Do not block light emanating from product in whole or part as this may cause an unsafe condition Never operate the fixture with missing or damaged lens Lens must be cl...

Page 4: ...Pull lamp leads into UPM housing and connect to driver secondary leads using approved wire connectors By Others NOTE See driver warning on page 1 Failure to comply with wiring requirements will void...

Page 5: ...LLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS Do not block light emanating from product in whole or part as this may cause an unsafe condition Never operate the fixture with missing or damage...

Page 6: ...crews evenly to 6 9 in lbs using a 5 64 allen wrench A B C 1 Install standard 4 5 x 2 85 recessed junction box by others in the final fixture location according to designed lighting plan NOTE Vertical...

Page 7: ...ND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS Do not block light emanating from product in whole or part as this may cause an unsafe condition Never operate the fixture with missing or damaged lens...

Page 8: ...ITE GROUND GREEN BARE WIRE IN UPM RED BLACK BLUE WHITE GREEN DRIVER 8 Use wire connectors By Others to connect driver primary leads to branch circuit wires Connect incoming ground and driver ground to...

Page 9: ...gasket is free of any dirt or debris Attach the faceplate by tightening the 4 6 32 captive screws evenly to 6 9 in lbs using a 5 64 allen wrench IMPORTANT SAFETY INFORMATION LISTED ON REVERSE READ FOL...

Page 10: ...CONTENTS OR TO MANUFACTURE USE OR SELL ANYTHING IT MAY DESCRIBE REPRODUCTION DISCLOSURE OR USE WITHOUT SPECIFIC WRITTEN AUTHORIZATION OF B K LIGHTING IS STRICTLY FORBIDDEN NOTES 1 THE SMALL CIRCLES AR...