REVISION DATE
12-13-11
REFERENCE
NUMBER
INS000795.6
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
5. Pull branch circuit wiring necessary for
installation (By Others.)
6. Attach tether wire under screw head at the base
of the UPM housing and tighten. Slowly lower
the faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM
is designed as an installation aid and NOT a
safety cable. Do not add weight to, or drop
faceplate.
Ground
Hot
Neutral
7. Use wire connectors (By Others) to connect driver
primary leads to branch circuit wires. Connect
incoming ground and driver ground to ground
wire provided in UPM housing. See wiring
diagram.
9. Make sure UPM housing gasket is free of
any dirt or debris. Attach the faceplate by
tightening the (4) #6-32 captive screws evenly
to 6-9 in/lbs using a 5/64” allen wrench.
4. Connect 1/2” conduit connector through female
threaded conduit entry.
NOTE: Surface conduit is a common entrance
for water if not properly sealed. Seal connector
threads and conduit pipe with a suitable sealant
(Teflon tape, adhesive, etc). Sealing the conduit
after knockouts are removed is required to
maintain warranty
Wiring Diagram.
8. Pull lamp leads into UPM housing and connect
to driver secondary leads using approved wire
connectors (By Others).
NOTE: See driver warning on page 1. Failure
to comply with wiring requirements will
void warranty.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
ETL LISTED
CONFORMS TO ANSI/UL
STANDARD 1598
CERTIFIED TO CAN/CSA
STANDARD C22.2 NO. 250
1. Remove Patented Knockout(s) as necessary from
the inside of the UPM housing for branch circuit
wiring and lamp leads to remote mounted
fixture. Leave remaining unused knockouts in
place to maintain seal.
NOTE: Patented design featuring a silicone ‘O’
Ring allowing knockout to be tapped back into
place to renew seal integrity.
2. Use adjustable strap provided to attach UPM
housing to tree. Tighten by pulling on the
adjustable strap until secure.
3.
Optional Step on PM1 & PM2:
Thread safety
cable through hole on the back of the UPM
housing. Feed safety cable through opposing
ends of the connector. Pull on wires to assure
the connection is secure. Leave enough slack in
safety cable for tree growth. Adjustments can
be made by pressing release spring with a pin or
3/64” allen tool.
PM2RM TREE STRAP™ Driver Housing
Constant Current Driver
LAMP
BLUE
WHITE
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
DRIVER