![B-K lighting PM2RM Installation Manual Download Page 8](http://html.mh-extra.com/html/b-k-lighting/pm2rm/pm2rm_installation-manual_3091701008.webp)
REVISION DATE
12-13-11
REFERENCE
NUMBER
INS000795.9
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
4. Attach the UPM housing at mounting brackets
with ¼” fasteners (by others). Use suitable
mounting hardware for surface.
NOTE: Many methods exist to bolt to a flat
surface. The fixture is provided with mounting
brackets with ¼” holes.
5. Connect 1/2” conduit connector through female
threaded conduit entry.
NOTE: Surface conduit is a common entrance
for water if not properly sealed. Seal connector
threads and conduit with a suitable sealant
(Teflon tape, adhesive, etc.). Sealing the
conduit after knockouts are removed is
required to maintain warranty.
6. Pull branch circuit wiring necessary for
installation (By Others.)
7. Attach tether wire under screw head at the base
of the UPM housing and tighten. Slowly lower
the faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM
is designed as an installation aid and NOT a
safety cable. Do not add weight to, or drop
faceplate.
Ground
Hot
Neutral
LAMP
BLUE
WHITE
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
DRIVER
8. Use wire connectors (By Others) to connect driver
primary leads to branch circuit wires. Connect
incoming ground and driver ground to ground
wire provided in UPM housing. See wiring
diagram.
Wiring Diagram.
9. Pull lamp leads into UPM housing and connect
to driver secondary leads using approved wire
connectors (By Others).
NOTE: See driver warning on page 1. Failure
to comply with wiring requirements will
void warranty.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
ETL LISTED
CONFORMS TO ANSI/UL
STANDARD 1598
CERTIFIED TO CAN/CSA
STANDARD C22.2 NO. 250
PM2RM SURFACE MOUNT Driver Housing
Constant Current Driver
1. Place provided template in final mounting
position according to designed lighting plan.
NOTE: Additional templates are available at
http://www.bklighting.com/templates
2. Drill holes into surface for ¼” fasteners (by
others) on locations illustrated on template.
3. Remove Patented Knockout(s) as necessary from
the inside of the UPM housing for branch circuit
wiring and lamp leads to remote mounted
fixture. Leave remaining unused knockouts in
place to maintain seal.
NOTE: Patented design featuring a silicone ‘O’
Ring allowing knockout to be tapped back into
place to renew seal integrity.