4.  Attach the UPM housing at mounting brackets 

with ¼” fasteners (by others). Use suitable 
mounting hardware for surface.

 

NOTE: Many methods exist to bolt to a flat 
surface. The fixture is provided with mounting 
brackets with ¼” holes. 

5.  Connect 1/2” conduit connector through female 

threaded conduit entry.

 

NOTE: Surface conduit is a common entrance 

for water if not properly sealed. Seal connector 
threads and conduit with a suitable sealant 

 

(Teflon tape, adhesive, etc.). Sealing the 
conduit after knockouts are removed is 
required to maintain warranty.

6.  Pull branch circuit wiring necessary for 

installation (By Others.)

7.  Attach tether wire under screw head at the base 

of the UPM housing and tighten. Slowly lower 
the faceplate until tether is taut. 

NOTE: Faceplate tether supplied with UPM 

is designed as an installation aid and NOT a 
safety cable. Do not add weight to, or drop 
faceplate.

Ground

Hot

Neutral

LAMP

BLUE

WHITE

QUICK DISCONNECT

LINE (BLACK)

NEUTRAL (WHITE)

GROUND (GREEN)

BARE WIRE

IN UPM

RED

BLACK

BLUE

WHITE

GREEN

DRIVER

8.  Use wire connectors (By Others) to connect driver 

primary leads to branch circuit wires. Connect 
incoming ground and driver ground to ground 
wire provided in UPM housing. See wiring 
diagram.

Wiring Diagram.

9.  Pull lamp leads into UPM housing and connect 

to driver secondary leads using approved wire 
connectors (By Others). 

NOTE: See driver warning on page 1. Failure 
to comply with wiring requirements will 

void warranty.

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

ETL LISTED

 CONFORMS TO ANSI/UL

STANDARD 1598

CERTIFIED TO CAN/CSA

STANDARD C22.2 NO. 250

PM2RM SURFACE MOUNT Driver Housing

Constant Current Driver

1.  Place provided template in final mounting 

position according to designed lighting plan. 

 

NOTE: Additional templates are available at 
http://www.bklighting.com/templates

2.  Drill holes into surface for ¼” fasteners (by 

others)  on locations illustrated on template. 

3.  Remove Patented Knockout(s) as necessary from 

the inside of the UPM housing for branch circuit 
wiring and lamp leads to remote mounted 
fixture. Leave remaining unused knockouts in 
place to maintain seal.

 

NOTE: Patented design featuring a silicone ‘O’ 
Ring allowing knockout to be tapped back into 
place to renew seal integrity.

Summary of Contents for PM2RM

Page 1: ...from product in whole or part as this may cause an unsafe condition Never operate the fixture with missing or damaged lens Lens must be cleaned on regular basis Entire fixture may become extremely hot...

Page 2: ...ntain warranty Wiring Diagram 8 Pull lamp leads into UPM housing and connect to driver secondary leads using approved wire connectors By Others NOTE See driver warning on page 1 Failure to comply with...

Page 3: ...TY AND INSTALLATION INSTRUCTIONS Do not block light emanating from product in whole or part as this may cause an unsafe condition Never operate the fixture with missing or damaged lens Lens must be cl...

Page 4: ...Pull lamp leads into UPM housing and connect to driver secondary leads using approved wire connectors By Others NOTE See driver warning on page 1 Failure to comply with wiring requirements will void...

Page 5: ...LLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS Do not block light emanating from product in whole or part as this may cause an unsafe condition Never operate the fixture with missing or damage...

Page 6: ...crews evenly to 6 9 in lbs using a 5 64 allen wrench A B C 1 Install standard 4 5 x 2 85 recessed junction box by others in the final fixture location according to designed lighting plan NOTE Vertical...

Page 7: ...ND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS Do not block light emanating from product in whole or part as this may cause an unsafe condition Never operate the fixture with missing or damaged lens...