background image

1.  Loosen three (3) captive #6-32 screws securing 

cap/socket assembly with 7/64” Allen wrench. 

 NOTE: Only one end cap (without ACV) is 

removable.

2.  Depress patented Anti-Condensation Valve™ 

(ACV™) to release vacuum and pull cap/socket 

assembly to access. Screws will be retained in 

cap. 

 

10"

(254mm)

"A/D" CAP

3" Dia.

(76mm)

2 11/16"

(68mm)

"B"/"E" CAP

(203mm)

8"

(76mm)

3" Dia.

2 11/16"

(68mm)

"C" CAP

(178mm)

7"

(76mm)

3" Dia.

Patented 360HD™

Mounting System

"B"/"E" CAP

3"

(76mm)

1"

(25mm)

"A"/"D" CAP

3"

(76mm)

5"

(127mm)

"C" CAP

2"

(51mm)

2 11/16"

(68mm)

YOSEMITE SERIES™

Remote - Solid State LED

Standard Installation 

40429 Brickyard Drive • Madera, CA 93636 • USA

559.438.5800 • FAX 559.438.5900 

www.bklighting.com • [email protected]

B-K LIGHTING

IMPORTANT SAFETY INFORMATION LISTED ON REVERSE

READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS

RELEASED

11-9-17

REFERENCE

 

NUMBER

INS-2573-00

6.   Loosen, then remove two (2) #4-40 screws from 

LED module using .050” Allen wrench.

7.  Carefully remove LED module from heatsink. 

 Do not pull on connector or wiring. Handle 

with care.

5.   Loosen four (4) #6-32 screws on wall wash optic 

holder using 7/64” Allen wrench, then gently 

pull away to remove from heatsink.

3.  Carefully pull out end cap assembly. LED is still 

attached to leads.

 Do not pull on connector or wiring. Handle 

with care.

LED and Optic Replacement

4.  Detach heatsink from fixture body via quick 

disconnect.

 Do not pull on connector or wiring. Handle 

with care.

 

Fragile! Do not pull on connector or wiring. 

Handle with care.

8.  Use small pick tool to push connector off 

LED board through two small slots behind 

connector. Once loose, lift connector upwards 

and off board. 

9.  Spread thin, even layer of thermal paste on back 

of new LED module. Place new LED module onto 

heatsink, lining up module with holes for screws. 

Tighten two (2) #4-40 screws using .050” Allen 

wrench to secure LED module to heatsink. 

Summary of Contents for HP2RM

Page 1: ... RM DRM Product must be installed by a qualified person in a manner consistent with its intended use and in compliance with the National Electrical Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product Before wiring to power supp...

Page 2: ... Patented 360HD Mounting System B E CAP 3 76mm 1 25mm A D CAP 3 76mm 5 127mm C CAP 2 51mm 2 11 16 68mm 1 Mount fixture onto suitable enclosure according to designed lighting plan 2 Secure NPS stem to mounting option Secure with provided locknut if applicable 3 Make watertight connections from remote driver to fixture leads using waterproof wire connectors By Others See wiring diagram Fixture Insta...

Page 3: ... NUMBER INS 2573 00 6 Loosen then remove two 2 4 40 screws from LED module using 050 Allen wrench 7 Carefully remove LED module from heatsink Do not pull on connector or wiring Handle with care 5 Loosen four 4 6 32 screws on wall wash optic holder using 7 64 Allen wrench then gently pull away to remove from heatsink 3 Carefully pull out end cap assembly LED is still attached to leads Do not pull o...

Page 4: ...e Solid State LED Standard Installation 40429 Brickyard Drive Madera CA 93636 USA 559 438 5800 FAX 559 438 5900 www bklighting com info bklighting com B K LIGHTING IMPORTANT SAFETY INFORMATION LISTED ON REVERSE READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS RELEASED 11 9 17 REFERENCE NUMBER INS 2573 00 14 Tighten three 3 captive 6 32 screws with 7 64 Allen wrench to secure cap assem...

Page 5: ...y become extremely hot Do not touch hot lens or fixture body Do not touch the lamp at any time Use a clean dry soft cloth to handle the lamp Oil from skin may damage the lamp and cause it to rupture Replace lamp only with correct wattage and type of lamp marked on fixture label All gaskets O rings and sealing surfaces must be kept clean during installation and service failure to do this may cause ...

Page 6: ...nal Electrical Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product Before wiring to power supply and during servicing turn off and lock out power at fuse or circuit breaker before service The use of accessory equipment not reco...

Page 7: ...ntrol wiring necessary for installation By Others Single Remote Driver with Dimming Controls 7 Connect branch circuit to terminal block Connect incoming ground to ground wire provided on NEMA 3R housing Connect secondary lamp leads to terminal See labels on terminal block for additional information 6 Pull secondary lamp leads necessary for installation though dedicated conduit By Others NOTE Failu...

Page 8: ...duit after knockouts are removed is required to maintain warranty 5 Pull branch circuit wiring necessary for installation By Others Pull dimming control wiring necessary for installation By Others Dual Remote Driver with Dimming Controls 6 Pull secondary lamp leads necessary for installation though dedicated conduit By Others NOTE Failure to comply with specific wiring requirements will void produ...

Page 9: ...an Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product Before wiring to power supply and during servicing turn off and lock out power at fuse or circuit breaker before service The use of accessory equipment not recommended by the manufacture...

Page 10: ...crews on Stability Flange to secure housing to EMT Remove excess EMT as needed 7 Per DIG IT Guide backfill the gap between the bottom of housing and bottom of hole with sand for drainage Housing Installation Threaded Entry Side Flats 1 Connect branch conduit connectors By Others to the junction box using either the threaded conduit entries on the bottom of the junction box or through holes drilled...

Page 11: ...ite Black Black White Hydrolock Plate Green Driver White Black White Blue Green LINE COM GROUND Orange Orange Brown Blue Black Gray FIXTURE FIXTURE Green Green Green DIM DIM DIM DIM DIM DIM Hydrolock Plate LINE COM GROUND FIXTURE FIXTURE DIM DIM 1 Remove temporary cover 2 Pull primary branch circuit wiring into junction box 3 Make watertight connections using waterproof wire connectors provided to...

Page 12: ...RTANT SAFETY INFORMATION LISTED ON REVERSE READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS 10 Remove any dirt or debris in O ring groove near top of housing Place O Ring inside of groove Failure to clean groove of debris will cause fixture to fail and void product warranty 11 Install faceplate using 1 8 Allen wrench and hand tighten the faceplate screws in a star pattern to 30 in lbs...

Page 13: ...lectrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product Before wiring to power supply and during servicing turn off and lock out power at fuse or circuit breaker before service The use of accessory equipment not recommended by the manufacturer or...

Page 14: ...re under screw head at the base of the UPM housing and tighten Slowly lower the faceplate until tether is taut NOTE Faceplate tether supplied with UPM is designed as an installation aid and NOT a safety cable Do not add weight to or drop faceplate Neutral 5 Connect 3 4 conduit connector through female threaded conduit entry NOTE Surface conduit is a common entrance for water if not properly sealed...

Page 15: ...era CA 93636 USA 559 438 5800 FAX 559 438 5900 www bklighting com info bklighting com B K LIGHTING IMPORTANT SAFETY INFORMATION LISTED ON REVERSE READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS RELEASED 12 8 17 REFERENCE NUMBER INS 2187 00 PM3RM TREE STRAP Driver Housing 10 Slide driver feet under two screws in UPM housing and tighten screws using Phillips screwdriver 11 Reinstall 8 ...

Page 16: ...ectrical Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product Before wiring to power supply and during servicing turn off and lock out power at fuse or circuit breaker before service The use of accessory equipment not recommende...

Page 17: ... not properly sealed Seal connector threads and conduit with a suitable sealant Teflon tape adhesive etc Sealing the conduit after knockouts are removed is required to maintain warranty Ground Hot Neutral 7 Pull branch circuit wiring and dimming control wiring necessary for installation By Others 8 Attach tether wire under screw head at the base of the UPM housing and tighten Slowly lower the face...

Page 18: ...7 REFERENCE NUMBER INS 2187 00 13 Make sure UPM housing gasket is free of any dirt or debris Attach the faceplate by tightening the 6 10 24 captive screws evenly using a 1 8 Allen wrench 11 Slide driver feet under two screws in UPM housing and tighten screws using Phillips screwdriver 12 Reinstall two 2 8 32 screws on other side of driver and tighten to secure driver to UPM housing PM3RM SURFACE M...

Page 19: ...ode Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product Before wiring to power supply and during servicing turn off and lock out power at fuse or circuit breaker before service The use of accessory equipment not recommended by the m...

Page 20: ... reattach UPM housing Ground Hot Neutral 4 Feed branch circuit wiring and dimming control wiring through mounting plate with CamLock assembly Attach mounting plate with supplied 2 10 24 stainless steel hex drive fasteners to universal ring using 1 8 Allen wrench 8 Attach tether wire under screw head at the base of the UPM housing Slowly lower the faceplate until tether is taut NOTE Faceplate tethe...

Page 21: ...Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product Before wiring to power supply and during servicing turn off and lock out power at fuse or circuit breaker before service The use of accessory equipment not recommended by the manufacturer o...

Page 22: ... connector through female threaded conduit entry NOTE Surface conduit is a common entrance for water if not properly sealed Seal connector threads and conduit pipe with a suitable sealant Teflon tape adhesive etc Sealing the conduit after knockouts are removed is required to maintain warranty 1 Loosen 6 10 24 captive screws using a 1 8 Allen wrench to remove faceplate of UPM housing WIRING DIAGRAM...

Page 23: ...38 5800 FAX 559 438 5900 www bklighting com info bklighting com B K LIGHTING IMPORTANT SAFETY INFORMATION LISTED ON REVERSE READ FOLLOW AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS RELEASED 12 8 17 REFERENCE NUMBER INS 2188 00 PM3DRM TREE STRAP Driver Housing 11 Slide driver feet under two screws in UPM housing and tighten screws using Phillips screwdriver 12 Reinstall 8 32 screws on other si...

Page 24: ...lectrical Code Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product Before wiring to power supply and during servicing turn off and lock out power at fuse or circuit breaker before service The use of accessory equipment not recommend...

Page 25: ...uit after knockouts are removed is required to maintain warranty Ground Hot Neutral 7 Pull branch circuit wiring and incoming dimming control wiring necessary for installation By Others 8 Attach tether wire under screw head at the base of the UPM housing and tighten Slowly lower the faceplate until tether is taut NOTE Faceplate tether supplied with UPM is designed as an installation aid and NOT a ...

Page 26: ... 17 REFERENCE NUMBER INS 2188 00 13 Make sure UPM housing gasket is free of any dirt or debris Attach the faceplate by tightening the 6 10 24 captive screws evenly using a 1 8 Allen wrench PM3DRM SURFACE MOUNT Driver Housing 10 Remove two 2 8 32 screws in UPM housing using Phillips screwdriver 11 Slide driver feet under two screws in UPM housing and tighten screws using Phillips screwdriver 12 Rei...

Page 27: ...e Canadian Electrical Code and all Local and Provincial Codes Follow product label information and instructions Qualified Personnel with appropriate personal protective equipment must perform all servicing of this product Before wiring to power supply and during servicing turn off and lock out power at fuse or circuit breaker before service The use of accessory equipment not recommended by the man...

Page 28: ...ock assembly Attach mounting plate with supplied 2 10 24 stainless steel hex drive fasteners to universal ring using 1 8 Allen wrench 8 Attach tether wire under screw head at the base of the UPM housing Slowly lower the faceplate until tether is taut NOTE Faceplate tether supplied with UPM is designed as an installation aid and NOT a safety cable Do not add weight to or drop faceplate WIRING DIAGR...