PROJECT:
TYPE:
Installation Instructions
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
RELEASED
12-8-17
REFERENCE
NUMBER
INS-2187-00
Ground
Hot
Neutral
LAMP
BLUE
WHITE
GROUND
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
Ground
Hot
Neutral
LAMP
BLUE
WHITE
GROUND
QUICK DISCONNECT
LINE (BLACK)
NEUTRAL (WHITE)
GROUND (GREEN)
BARE WIRE
IN UPM
RED
BLACK
BLUE
WHITE
GREEN
BALLAST
13. Make sure UPM housing gasket is free of any
dirt or debris. Attach the faceplate by tightening
the (6) #10-24 captive screws evenly using a 1/8”
Allen wrench.
11. Slide driver feet under two screws in UPM
housing and tighten screws using Phillips
screwdriver.
12. Reinstall two (2) #8-32 screws on other side
of driver and tighten to secure driver to UPM
housing.
PM3RM SURFACE MOUNT™
Driver Housing
10. Remove two (2) #8-32 screws in UPM housing
using Phillips screwdriver.