40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
RELEASED
3-2 -1
REFERENCE NUMBER
INS-2
-00
14. Make sure UPM housing gasket is free of any
dirt or debris. Attach the faceplate by tightening
the (6) #10-24 captive screws evenly using a 1/8”
Allen wrench.
PM2DRM ROUND CAMLOCK™
Inspiration Control System
iOS device (Not Included) with installed B-K Lighting Inspiration Application required for use.
12. Attach tether wire under screw head at the base
of the UPM housing and tighten. Slowly lower the
faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM is
designed as an installation aid and NOT a safety
cable. Do not add weight to, or drop faceplate.
Ground
Hot
Neutral
13. Use wire connectors (By Others) to connect driver
primary leads to branch circuit wires. Connect
incoming ground to ground wire provided in
UPM housing.
See wiring diagram.
WIRING DIAGRAM - Wireless Bluetooth® Controls
with Inspiration Application on iOS device
LINE
MODULE
COM
Remote
Driver
Red
Black
iOS
Bluetooth®
GROUND
iOS device must be within 5ft of fixture for
wireless operation.
iOS device controls dimming, CCT, Saturation,
and Hue using Bluetooth® wireless controls and
the application.
LINE
MODULE
COM
GROUND
Remote
Driver
10V
0V
0-10V DIM -
0-10V DIM +
Red
Black
0-10V CCT +
0-10V CCT -
Dimming
Continuous
CCT
10V
0V
iOS
Bluetooth®
WIRING DIAGRAM - Hybrid
Secondary wiring from remote driver connects
to fixture leads. 0-10V dimming connects to
module. 0-10V Continuous CCT connects to
module. iOS device controls CCT, Saturation, and
Hue.
iOS device must be within 5ft of fixture for
wireless operation.
LINE
MODULE
COM
GROUND
Remote
Driver
10V
0V
0-10V DIM -
0-10V DIM +
Red
Black
0-10V CCT DIM +
0-10V CCT DIM -
Dimming
Continuous
CCT
10V
0V
WIRING DIAGRAM - 0-10V Wired
Secondary wiring from remote driver connects
to fixture leads. 0-10V dimming connects to
module. 0-10V Continuous CCT connects to
module and controls CCT, Saturation, and Hue.
iOS device must be within 5ft of fixture for