RELEASE DATE
3-15-1
REFERENCE NUMBER
INS-24 2-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
5. Pull branch circuit wiring necessary for
installation (By Others.)
6. Attach tether wire under screw head at the base
of the UPM housing and tighten. Slowly lower
the faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM
is designed as an installation aid and NOT a
safety cable. Do not add weight to, or drop
faceplate.
4. Connect 1/2” conduit connector through female
threaded conduit entry.
NOTE: Surface conduit is a common entrance
for water if not properly sealed. Seal connector
threads and conduit pipe with a suitable
sealant (Teflon tape, adhesive, etc). Sealing
the conduit after knockouts are removed is
required to maintain warranty
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
1. Remove faceplate, then remove Patented
Knockout(s) as necessary from the inside of
the UPM housing for branch circuit wiring and
remote fixture leads. Leave remaining unused
knockouts in place to maintain seal.
NOTE: Patented design featuring a silicone ‘O’
Ring allowing knockout to be tapped back into
place to renew seal integrity.
2. Use adjustable strap provided to attach UPM
housing to tree. Tighten by pulling on the
adjustable strap until secure.
3. Thread safety cable through hole on the back
of the UPM housing. Feed safety cable through
opposing ends of the connector. Pull on wires to
assure the connection is secure. Leave enough
slack in safety cable for tree growth. Adjustments
can be made by pressing release spring with a pin
or 3/64” Allen tool.
PM2RM TREE STRAP™
Inspiration Control System
iOS device (Not Included) with installed B-K Lighting Inspiration Application required for use.
WIRING DIAGRAM - Wireless Bluetooth® Controls
with Inspiration Application on iOS device
LINE
MODULE
COM
Remote
Driver
Red
Black
iOS
Bluetooth®
GROUND
iOS device must be within 5ft of fixture for
wireless operation.
iOS device controls dimming, CCT, Saturation,
and Hue using Bluetooth® wireless controls and
the application.
LINE
MODULE
COM
GROUND
Remote
Driver
10V
0V
0-10V DIM -
0-10V DIM +
Red
Black
0-10V CCT +
0-10V CCT -
Dimming
Continuous
CCT
10V
0V
iOS
Bluetooth®
WIRING DIAGRAM - Hybrid
Secondary wiring from remote driver connects
to fixture leads. 0-10V dimming connects to
module. 0-10V Continuous CCT connects to
module. iOS device controls CCT, Saturation,
and Hue.
iOS device must be within 5ft of fixture for
wireless operation.
LINE
MODULE
COM
GROUND
Remote
Driver
10V
0V
0-10V DIM -
0-10V DIM +
Red
Black
0-10V CCT DIM +
0-10V CCT DIM -
Dimming
Continuous
CCT
10V
0V
WIRING DIAGRAM - 0-10V Wired
Secondary wiring from remote driver connects
to fixture leads. 0-10V dimming connects to
module. 0-10V Continuous CCT connects to
module and controls CCT, Saturation, and Hue.
iOS device must be within 5ft of fixture for
wireless operation.
7. Use waterproof wire connectors (By Others) to
connect driver primary leads to branch circuit
wires. Connect incoming ground to ground wire
provided in UPM housing. Connect secondary
side to remote fixture leads.
See wiring diagram.
Ground
Hot
Neutral
Number of wires and connections varies with
wiring as per lighting plan.