RELEASE DATE
3-15-1
REFERENCE NUMBER
INS-24 3-00
40429 Brickyard Drive • Madera, CA 93636 • USA
559.438.5800 • FAX 559.438.5900
www.bklighting.com • [email protected]
B-K LIGHTING
4. Attach the UPM housing at mounting brackets
with ¼” fasteners (By Others). Use suitable
mounting hardware for surface.
NOTE: Many methods exist to bolt to a flat
surface. The fixture is provided with mounting
brackets with ¼” holes.
5. Connect 1/2” conduit connector through female
threaded conduit entry.
NOTE: Surface conduit is a common entrance
for water if not properly sealed. Seal connector
threads and conduit with a suitable sealant
(Teflon tape, adhesive, etc.). Sealing the
conduit after knockouts are removed is
required to maintain warranty.
6. Pull branch circuit wiring necessary for
installation (By Others.)
7. Attach tether wire under screw head at the base
of the UPM housing and tighten. Slowly lower
the faceplate until tether is taut.
NOTE: Faceplate tether supplied with UPM
is designed as an installation aid and NOT a
safety cable. Do not add weight to, or drop
faceplate.
IMPORTANT SAFETY INFORMATION LISTED ON REVERSE
READ, FOLLOW, AND SAVE ALL SAFETY AND INSTALLATION INSTRUCTIONS
1. Decide final mounting position according to
designed lighting plan.
2. Drill holes into surface for ¼” fasteners (By
Others).
3. Remove Patented Knockout(s) as necessary from
the inside of the UPM housing for branch circuit
wiring and lamp leads to remote mounted
fixture. Leave remaining unused knockouts in
place to maintain seal.
NOTE: Patented design featuring a silicone ‘O’
Ring allowing knockout to be tapped back into
place to renew seal integrity.
PM2RM SURFACE MOUNT™
Inspiration Control System
iOS device (Not Included) with installed B-K Lighting Inspiration Application required for use.
8. Use waterproof wire connectors (By Others)
to connect driver primary leads to branch
circuit wires. Connect incoming ground and
driver ground to ground wire provided in UPM
housing. See wiring diagram.
Number of wires and connections varies with
wiring as per lighting plan.
Ground
Hot
Neutral
WIRING DIAGRAM - Wireless Bluetooth® Controls
with Inspiration Application on iOS device
LINE
MODULE
COM
Remote
Driver
Red
Black
iOS
Bluetooth®
GROUND
iOS device must be within 5ft of fixture for
wireless operation.
iOS device controls dimming, CCT, Saturation,
and Hue using Bluetooth® wireless controls and
the application.
LINE
MODULE
COM
GROUND
Remote
Driver
10V
0V
0-10V DIM -
0-10V DIM +
Red
Black
0-10V CCT +
0-10V CCT -
Dimming
Continuous
CCT
10V
0V
iOS
Bluetooth®
WIRING DIAGRAM - Hybrid
Secondary wiring from remote driver connects
to fixture leads. 0-10V dimming connects to
module. 0-10V Continuous CCT connects to
module. iOS device controls CCT, Saturation,
and Hue.
iOS device must be within 5ft of fixture for
wireless operation.