IMediaChassis Series
22
INSTALLING APPLICATIONS MODULES
To install a module:
1. Remove the blank bracket (if present) covering the slot where the module
will be installed. B+B SmartWorx recommends installing blank brackets in
unused module slots.
2. Slide the module into the chassis using the card guides.
3. Secure the module to the chassis by tightening the captive screw. (Refer to
the documentation shipped with the module for configuration information.)
In order to manage an iMediaChassis series, the SNMP Management Module
needs to be installed in the appropriate slot of the chassis.
Install the iMediaChassis/3 slot SNMP Management Module into the bottom
left slot.
NOTE
This slot is ONLY for the Management Module; do not install Application Modules such
as media conversion and mode conversion modules in this slot.
Figure 12: SNMP Module Slot on iMediaChassis/3
SNMP W RITE LOCK
The SNMP Write Lock switch is located on the back of the iMediaChassis/3. The
SNMP Write Lock switch prevents a new management board from re-configuring
the application module settings (e.g., the status of features such as LinkLoss,
FiberAlert, Force mode, etc.) made via SNMP on
any previous Management Modules.