IMediaChassis Series
16
FANS
Users can define a threshold for fan operation via SNMP (when installed in a
managed environment). If a fan’s speed falls below the specified level, SNMP
sends a Trap (configured in iView²) to the administrator. There are also two LED
indicators on the SNMP Management Module for fan failure.
SNMP Management Modules include two twisted pair ports, one for management
and one reserved for future use. The Management Module also features a DB9
serial port, and supports SNMP V1/V2c.
Installing Management and Application (iMcV-) Modules
INSTALLING APPLICATIONS MODULES
To install a module:
1. Remove the blank bracket (if present) covering the slot where the module
will be installed. B+B SmartWorx recommends installing blank brackets in
unused module slots.
2. Slide the module into the chassis using the card guides.
3. Secure the module to the chassis by tightening the captive screw. (Refer to
the documentation shipped with the module for configuration information.)
4. When installing modules observe ESD precautions, refer to the Electrostatic
Discharge Precautions section.
In order to manage an iMediaChassis series, the SNMP Management Module
needs to be installed in the appropriate slot of the chassis.
Install the iMediaChassis/6 slot into the first slot on the far left of the chassis.
NOTE
This slot is ONLY for the Management Module; do not install Application Modules such as
media conversion and mode conversion modules into this slot.
Figure 10: SNMP Module location for iMediaChassis/6