Azure c150, c200, c300, c400, c500, c600 User Manual Download Page 6

Azure™ cSeries User Manual

Page 5

1. Introduction

The  Azure  cSeries  imaging  systems  offer 

high performance imaging for a wide 

variety of applications. The cSeries family 

of instruments includes the follow products: 

c150, c200, c300, c400, c500 and c600.

Select which one fits your applications now, 

and learn more about upgrading later when 

your needs change.

Each Azure cSeries imaging workstation 

can  be  upgraded  in  the  field  to  a  higher 

model with a wider range of applications, 

with the exception of the c150 which 

is not upgradeable. Contact us at 

[email protected]

 to learn more.

The Azure cSeries system includes the following key components:
 

•  Cabinet

 

– The cabinet is a light tight image station.

 

•   Camera – High resolution camera, preinstalled in the system. A motorized lens is included on 

the c300 systems and above.

 

•   UV Transilluminator – The UV illuminator provides 302nm and 365nm trans illumination. It is 

mounted on a pull out tray. 

 

•   EPI Blue and White LEDs – The cabinet also contains EPI white and blue light panels on each 

side of the cabinet interior walls. 

 

•   EPI RGB LEDs – High intensity LED illuminators (c400 and c600).

 

•  EPI 660nm & 785nm Laser Diodes (c500 and c600).

 

•  Filters – For each light source, appropriate filters are also included in the motorized filter wheel. 

 

•   Tablet PC – The tablet PC is a self contained touch screen PC for system control and image 

acquisition.

 

•  Orange Tray – For Visible dyes, the orange tray converts UV light into Visible light.

 

•   Blot Tray – Stored in the cSeries door, the Blot Tray is required for imaging all blots. For 

fluorescent blots, it is placed on the UV transilluminator. For Chemi blots, it can be placed on 

the UV transilluminator, or on the chemi shelf in the cabinet. 

 

•   USB Memory Stick – The Azure Biosystems memory stick contains files relevant to your 

imaging system.

 

•   AzureSpot Analysis Software – Please contact our technical support to receive your 

electronical license at 

[email protected]

.

c600

c500

c400

c300

c200

c150

Summary of Contents for c150, c200, c300, c400, c500, c600

Page 1: ...Azure cSeries User Manual Page 1 Azure cSeries User Manual for the c150 c200 c300 c400 c500 and c600 NIR RGB CHEMI WHITE LIGHT BLUE LIGHT UV Rev 20150428...

Page 2: ...coming in through the sides or around the lenses Always cover all skin that may be exposed to UV light especially the face neck hands and arms Always make sure that any UV protection devices such as t...

Page 3: ...al illumination sources Right and left laser modules located in the c500 and c600 imaging chamber are installed in a highly diffused protective metal enclosure preventing exposure to full laser radiat...

Page 4: ...however are specifically excluded Defects caused by improper operation Repair or modification done by anyone other than Azure Biosystems or the company s authorized agent Use of spare parts supplied b...

Page 5: ...3 2A Imaging Workflow 9 3 2B Band Excision and Light Safety Switch 10 3 3 Chemiluminescent Applications c300 systems and above 10 3 3A Imaging Workflow for Chemiluminescent Applications 11 3 4 RGB App...

Page 6: ...5nm trans illumination It is mounted on a pull out tray EPI Blue and White LEDs The cabinet also contains EPI white and blue light panels on each side of the cabinet interior walls EPI RGB LEDs High i...

Page 7: ...ter solvents or corrosive materials on a flat and stable surface with adequate clearance on all sides The system must remain stationary during operation Further the system should be placed away from i...

Page 8: ...ng screen during initialization Once the system is done initializing the software displays the gallery tab and is ready to use 2 5 Attach Other USB Input Devices to the System You may attach regulator...

Page 9: ...ll display your image with dark and light pixels reversed SATURATION Selecting Saturation will show you images with intensities beyond the dynamic range of the camera SINGLE MULTICHANNELVIEWING When a...

Page 10: ...ht source for gels that are stained with dyes that excite in the blue range Visible For dyes that are visible without additional excitation use the Visible light source When selected the software will...

Page 11: ...he resolution of the camera and image At the Lowest sensitivity setting you will be taking a full resolution image with the camera And the Highest sensitivity setting the resulting image will be 0 3 M...

Page 12: ...amera Recommendation Set the exposure time to 30 Seconds by hitting 3 then 0 and then S Keep the Sensitivity setting on the default setting NORMAL Select CUMULATIVE After hitting CAPTURE a series of i...

Page 13: ...e time 5 Select CAPTURE The channels will be captured sequentially 6 The resulting image will be displayed in the gallery tab 3 5 NIR Applications c500 and c600 For all NIR blots use the Blot Tray on...

Page 14: ...d like them assigned to Set the exposure time for each channel 3 Select the aperture setting the smaller the number the wider the aperture For chemiluminescence we recommend 0 95 for fastest light gat...

Page 15: ...CUS CALIBRATION Allows the technician to reset the focus setting in case of a shift in focus CREATE FLATS Allows the technician to recreate flat calibration files 5 Help Selecting the help tab will al...

Page 16: ...ower Off Restart the Tablet To turn off the system shut down the tablet by a Swiping from the right to left on the right side of the screen to bring up the right side toolbar b Select SETTINGS c Selec...

Page 17: ...st of programs to uninstall select CSERIES CAPTURE SOFTWARE 4 Once it is uninstalled you can begin installing the new software 5 Select the SETUP file in the new software folder 6 Select RUN from the...

Page 18: ...the default 12 If it asks you to replace the existing cSeries folder select YES then INSTALL 13 On the CP210x USB to UART Bridge Driver Installer screen select NEXT 14 On the next screen accept the ag...

Page 19: ...the software and make sure the hardware is turned on and re launch the software Copyright 2013 Azure Biosystems Inc All rights reserved The Azure Biosystems logo and Azure are trademarks of the Compan...

Reviews: