Safety and Regulatory Compliance

Important Safety Information

Please read these instructions before operating the Azure™ cSeries imaging system.

UV Safety Precautions

The Azure™ cSeries system comes with a built-in Ultra-Violet (UV 200-400nm) Transilluminator inside 

the system. Exposure to UV radiation can cause permanent damage to the eyes and skin. The system 

enclosure confines the radiation within the system and shields the user from exposure. The system 

is also equipped with a two-way safety interlock switch which automatically cuts off the power to the 

transilluminator when the door is open during normal use.
The Azure cSeries imaging systems belongs to Class A equipment, and fulfills the limit values of table 

3 but not table 4 of EN 61326:1997+A1+A2+A3. It may become necessary to defeat the safety lock or 

operate the transilluminator outside the system for service. In this case, be sure to use the following 

safety precautions:
 

•   Always wear UV-protected eyewear that is specified by the manufacturer as providing 

protection at the wavelength(s) used, making sure that the eyewear protects any areas where 

radiation may come through (UV sunglasses may not prevent UV radiation from coming in 

through the sides or around the lenses). 

 

•   Always cover all skin that may be exposed to UV light, especially the face, neck, hands, and 

arms.

 

•   Always make sure that any UV protection devices (such as the safety switch on the light 

cabinet apparatus) are working properly. If not, discontinue use until the device(s) are properly 

repaired.

 

•  Please use only UV lamps in the transilluminator.

Electrical Safety Precautions

Be sure to take proper precautions when handling any electrical equipment. NEVER work on any live 

circuit, fixture, receptacle, or switch. Safety rules you should follow whenever working with any electrical 

appliance include:
 

•  Always shut off power at the main disconnect before changing a fuse.

 

•  Always shut off power to the circuit before repairing or replacing a switch, receptacle, or fixture.

 

•  Always tape over the main switch, empty fuse socket, or circuit breaker you are working on.

 

•   Always check that the circuit is dead before beginning work on it. Using a circuit tester or 

voltmeter can help you determine this.

 

•  Always unplug any appliance before repairing it.

    

Protective earth terminal

      

The earth terminal, intended for connection to an external protective conductor for protection against 

electric shock in case of a fault, is located on the inside of the back panel.

CAUTION

Because U.V. radiation can cause serious damage 

to unprotected eys and skin, we recommend to 

wear U.V. protection glasses or face shield.

UV

Summary of Contents for c150, c200, c300, c400, c500, c600

Page 1: ...Azure cSeries User Manual Page 1 Azure cSeries User Manual for the c150 c200 c300 c400 c500 and c600 NIR RGB CHEMI WHITE LIGHT BLUE LIGHT UV Rev 20150428...

Page 2: ...coming in through the sides or around the lenses Always cover all skin that may be exposed to UV light especially the face neck hands and arms Always make sure that any UV protection devices such as t...

Page 3: ...al illumination sources Right and left laser modules located in the c500 and c600 imaging chamber are installed in a highly diffused protective metal enclosure preventing exposure to full laser radiat...

Page 4: ...however are specifically excluded Defects caused by improper operation Repair or modification done by anyone other than Azure Biosystems or the company s authorized agent Use of spare parts supplied b...

Page 5: ...3 2A Imaging Workflow 9 3 2B Band Excision and Light Safety Switch 10 3 3 Chemiluminescent Applications c300 systems and above 10 3 3A Imaging Workflow for Chemiluminescent Applications 11 3 4 RGB App...

Page 6: ...5nm trans illumination It is mounted on a pull out tray EPI Blue and White LEDs The cabinet also contains EPI white and blue light panels on each side of the cabinet interior walls EPI RGB LEDs High i...

Page 7: ...ter solvents or corrosive materials on a flat and stable surface with adequate clearance on all sides The system must remain stationary during operation Further the system should be placed away from i...

Page 8: ...ng screen during initialization Once the system is done initializing the software displays the gallery tab and is ready to use 2 5 Attach Other USB Input Devices to the System You may attach regulator...

Page 9: ...ll display your image with dark and light pixels reversed SATURATION Selecting Saturation will show you images with intensities beyond the dynamic range of the camera SINGLE MULTICHANNELVIEWING When a...

Page 10: ...ht source for gels that are stained with dyes that excite in the blue range Visible For dyes that are visible without additional excitation use the Visible light source When selected the software will...

Page 11: ...he resolution of the camera and image At the Lowest sensitivity setting you will be taking a full resolution image with the camera And the Highest sensitivity setting the resulting image will be 0 3 M...

Page 12: ...amera Recommendation Set the exposure time to 30 Seconds by hitting 3 then 0 and then S Keep the Sensitivity setting on the default setting NORMAL Select CUMULATIVE After hitting CAPTURE a series of i...

Page 13: ...e time 5 Select CAPTURE The channels will be captured sequentially 6 The resulting image will be displayed in the gallery tab 3 5 NIR Applications c500 and c600 For all NIR blots use the Blot Tray on...

Page 14: ...d like them assigned to Set the exposure time for each channel 3 Select the aperture setting the smaller the number the wider the aperture For chemiluminescence we recommend 0 95 for fastest light gat...

Page 15: ...CUS CALIBRATION Allows the technician to reset the focus setting in case of a shift in focus CREATE FLATS Allows the technician to recreate flat calibration files 5 Help Selecting the help tab will al...

Page 16: ...ower Off Restart the Tablet To turn off the system shut down the tablet by a Swiping from the right to left on the right side of the screen to bring up the right side toolbar b Select SETTINGS c Selec...

Page 17: ...st of programs to uninstall select CSERIES CAPTURE SOFTWARE 4 Once it is uninstalled you can begin installing the new software 5 Select the SETUP file in the new software folder 6 Select RUN from the...

Page 18: ...the default 12 If it asks you to replace the existing cSeries folder select YES then INSTALL 13 On the CP210x USB to UART Bridge Driver Installer screen select NEXT 14 On the next screen accept the ag...

Page 19: ...the software and make sure the hardware is turned on and re launch the software Copyright 2013 Azure Biosystems Inc All rights reserved The Azure Biosystems logo and Azure are trademarks of the Compan...

Reviews: