MOUNTING YOUR AZ-TECH SOUND UNIT

 

 

Consider the following criteria when mounting the unit:-

 

 

 

Mount high enough to deter potential tampering and to afford some shelter.

 

 

(preferably under the eaves). 

 

 

 

Mount in a prominent location so as to maximise the deterrent effect.

 

 

 

Ensure that you have adequate cable access to your chosen location.

 

 

 

Try to select a flat even mounting surface to ensure the rear micro-switch tamper  

 

mechanism locates correctly against the wall surface.  

 

 

(

Note: 

Where mounting surfaces are uneven you may need to bend  the micro-switch blade 

 

to effect a good solid contact against the wall surface thus ensuring reliable operation of  

 

the front / rear  tamper mechanism).

 

 

 

There are five screw mounting holes on the units backplate to ensure secure fixing even 

where the mounting surface may be uneven.

 

 
N.B 

When mounting the unit upon a brick wall, BS4737 specifies that a minimum of  3 x No.10 

size steel screws be used. They must penetrate the brick itself by at least 40mm using  
appropriate wall plugs.

 

 

Drill all holes required for mounting the unit, using the positioning template provided on the rear 
of the cardboard outer box, and insert wall plugs.

 

 

Affix the Sound Unit backplate to the exterior wall ensuring that your connecting  cable has been 
inserted through the appropriate cable entry hole.

 

 

INSTALLATION & WIRING OF YOUR AZ-TECH SOUND UNIT

 

 

Connecting the Sound Unit to the Alarm Control Panel:

 

 

Utilising the terminal connectors to the left side of your Sounder’s PCB, wire in as follows:-

 

 

TAMPER RETURN :  

Negative tamper return 

BELL TRIGGER :

 

 

Negative applied output to activate the Sounder

 

SUPPLY (12V+) :

 

 

Permanent positive supply

  

SUPPLY(OV-) :

  

 

Permanent negative supply 

 

STROBE (-) :

   

 

Negative applied output to activate Strobe

 

 

We recommend you wire into the Sound Unit first and the Control Panel second.

 

 
 
 
 
 

NB: 

If you are wiring in a basic model 

AZ-120 

unit ( ie. without SAB function  

or anti-tamper) then you do not need to connect  to the TAMPER RETURN.  
However you do need to place a link between the M/SWTCH Terminals to  
bypass this function.  ( See Fig.1) 

 

 
 

Your AZ-TECH Sounder is compatible with most Intruder Alarm Control Panels. Please see the 
table at the rear of this booklet that illustrates connection to many of the most  popular Control 
Panels available. If your Alarm panel is not listed in our table please refer to your Alarm Panel  
Installation manual for appropriate wiring instructions.  

 

+ SIRE

N

 -

 

M/SW

 

‘Lin

k’

 

AZ-120 ( Fig.1)

 

Summary of Contents for AZ-120

Page 1: ...AZ TECH EXTERNAL SOUNDERS Quality through People products INSTALLATION GUIDE...

Page 2: ...al Sound Unit Sounder Connections Page 4 Set up and Operation procedure Page 5 Indications of Alarm status Flashing LED indicators Installing Multiple Units Connecting two or more units Page 6 Safety...

Page 3: ...alone SAB SCB operation and trickle charge of the battery when a hold off voltage is applied SAB SCB SAB Self activating Bell unit The standard sounder operating mode providing maximum sounder volume...

Page 4: ...of the cardboard outer box and insert wall plugs Affix the Sound Unit backplate to the exterior wall ensuring that your connecting cable has been inserted through the appropriate cable entry hole INST...

Page 5: ...ront cover over the backplate and locate into position You should hear the click of the microswitch depressing as the cover locates Secure with the fixing screw provided and insert the protective scre...

Page 6: ...from the Control Panel ie as a result of someone cutting the connecting cable to the Sound Unit or due to total loss of Power to the Control panel INSTALLING MULTIPLE UNITS If more than one Sound Unit...

Page 7: ...e their own method of testing the strobe and siren which should be utilised Failing that simply arm the system and cause an alarm activation to confirm correct operation of the External Sound unit Tem...

Page 8: ...Panels AZTECH ESU SABT TAMP RTN BELL BELL TR HO SUPPLY HO SUPPLY STR STROBE Connections For A1 OMNICRON MICROMARK STROBE NOT CONNECTED AZTECH ESU SCB RT TAMP RTN BELL BELL TR BELL SUPPLY SCB A SUPPLY...

Page 9: ...ST ST Connections For PYRONIX Control Panels Paragon E Plus Conqueror Super Sterling 10 Matrix Euro AZTECH ESU TAMP RTN BELL TR SUPPLY SUPPLY STROBE Castle BT BT BT TR BA BELL NO PGM1 NO BELL B S or B...

Page 10: ...ingle Piezo Single Piezo Twin Piezo Strobe Xenon tube 90 flashes min 90 flashes min 90 flashes min Indication Twin LED Twin LED Twin LED SAB SCB YES YES Timer Panel determined 15 9 minute cut off 5 se...

Page 11: ...s Fax E Mail Post Code Which distributors do you 1 regularly buy from 2 3 How many Alarm Systems do you install each month How many of the following Kinetic products do use each month EXTERNAL SOUND U...

Page 12: ...Kinetic Electronics Limited Unit 7 Stakehill Industrial Estate Middleton Manchester M24 2RW Tel 0161 654 9595 Fax 0161 654 9596 Email sales kinetic security co uk www kinetic security co uk RoHS...

Reviews: