SAFETY

 

 

Installation and maintenance should only be carried out by qualified personnel.

 

 

 

All strobes generate high voltages which can remain for some time after the supply has been 
removed. 

NEVER

 activate the strobe whilst the PCB is outside of its protective case. 

 

 

For maintenance purposes, should you need to access the circuit by removing the PCB 
protective cover, avoid touching that part of the circuit labelled 

WARNING HIGH VOLTAGE’  

to eliminate the risk of electric shock. 

 

 

SERVICING

 

 

If you need to access the External Sound Unit for maintenance purposes, ensure that the Control 
Panel is in 

DAY

 or 

UNSET

 mode. Lift the front cover from the Sounder. You can now work on the 

Unit without it sounding. ( Any internal sounder on your Alarm system will activate at this point 
and will need to be deactivated from the control panel if necessary).

 

 

Most Control Panels have their own method of testing the strobe and siren which should be 
utilised. Failing that, simply arm the system and cause an alarm activation to confirm correct 
operation of the External Sound unit.

 

 

Temporarily disconnect the positive supply to the unit at the Control Panel to confirm that the 
sounder self activates.

 

 

Replace the Sounder’s cover ensuring that the battery jumper is in the 

ON

 position and the timer 

jumper set to 

9

 or 

15

 minutes as required. 

 

WARRANTY

 

 

This product is warranted free from defects caused by design or manufacture for a period of two 
years from date of manufacture. 
 
Provided that the goods have not been modified, altered or misused in any way, the company 
guarantees  at its sole discretion to refund the price of, replace free of charge or to repair said 
faulty goods. 
 
The external Sound Unit does not constitute a complete alarm system, merely a component part 
thereof, and Kinetic Electronics Limited cannot accept responsibility  or liability for any damages 
claim whatsoever based on a claim that the unit failed to function correctly. 

Summary of Contents for AZ-120

Page 1: ...AZ TECH EXTERNAL SOUNDERS Quality through People products INSTALLATION GUIDE...

Page 2: ...al Sound Unit Sounder Connections Page 4 Set up and Operation procedure Page 5 Indications of Alarm status Flashing LED indicators Installing Multiple Units Connecting two or more units Page 6 Safety...

Page 3: ...alone SAB SCB operation and trickle charge of the battery when a hold off voltage is applied SAB SCB SAB Self activating Bell unit The standard sounder operating mode providing maximum sounder volume...

Page 4: ...of the cardboard outer box and insert wall plugs Affix the Sound Unit backplate to the exterior wall ensuring that your connecting cable has been inserted through the appropriate cable entry hole INST...

Page 5: ...ront cover over the backplate and locate into position You should hear the click of the microswitch depressing as the cover locates Secure with the fixing screw provided and insert the protective scre...

Page 6: ...from the Control Panel ie as a result of someone cutting the connecting cable to the Sound Unit or due to total loss of Power to the Control panel INSTALLING MULTIPLE UNITS If more than one Sound Unit...

Page 7: ...e their own method of testing the strobe and siren which should be utilised Failing that simply arm the system and cause an alarm activation to confirm correct operation of the External Sound unit Tem...

Page 8: ...Panels AZTECH ESU SABT TAMP RTN BELL BELL TR HO SUPPLY HO SUPPLY STR STROBE Connections For A1 OMNICRON MICROMARK STROBE NOT CONNECTED AZTECH ESU SCB RT TAMP RTN BELL BELL TR BELL SUPPLY SCB A SUPPLY...

Page 9: ...ST ST Connections For PYRONIX Control Panels Paragon E Plus Conqueror Super Sterling 10 Matrix Euro AZTECH ESU TAMP RTN BELL TR SUPPLY SUPPLY STROBE Castle BT BT BT TR BA BELL NO PGM1 NO BELL B S or B...

Page 10: ...ingle Piezo Single Piezo Twin Piezo Strobe Xenon tube 90 flashes min 90 flashes min 90 flashes min Indication Twin LED Twin LED Twin LED SAB SCB YES YES Timer Panel determined 15 9 minute cut off 5 se...

Page 11: ...s Fax E Mail Post Code Which distributors do you 1 regularly buy from 2 3 How many Alarm Systems do you install each month How many of the following Kinetic products do use each month EXTERNAL SOUND U...

Page 12: ...Kinetic Electronics Limited Unit 7 Stakehill Industrial Estate Middleton Manchester M24 2RW Tel 0161 654 9595 Fax 0161 654 9596 Email sales kinetic security co uk www kinetic security co uk RoHS...

Reviews: