3.1.6
Electrical connections
•
The electrical connections must comply with the local regulations of the country where the
machine will be installed.
•
The mains voltage must be the same as that shown on the machine
’
s dataplate.
•
Please bear in mind the following:
o
The phase must feature
fuse protection
with the nominal capacity according to the
electrical data of the dataplate installed on the machine, next to the serial number.
o
The
machine can be disconnected
from the mains
on all poles
.
o
The room
’
s electrical installation must
comply with the IEC 364 regulations
. To
increase the safety levels, the power plug must be connected
to an earth leakage
protection device with a nominal current of 30 mA (differential), according to EN
61008
.
o
Never
operate the machine with a
damaged power supply cable
. Contact the
technical service to solve this problem.
o
Do not pull from the power cable
to disconnect it from the socket.
o
Do not touch
mechanisms with
wet hands or feet
.
o
Do not connect or touch the machine if you are barefoot
.
Do not exceed the maximum length of the suction tube. Failing to
observe this could cause permanent damage to the milk pump and
not guarantee the effectiveness of the cleaning cycles. The warranty
does not cover damage caused by this.