background image

 

                                                                                                                                                             

 

 

         

 

 

1ª    10012 - E    02 - 2006 

 

18

A14. Product door

 

Made of polycarbonate, its main purpose is to prevent the entry of insects into the machine. It 
can be removed by removing the holding plate on the interior of the machine. 

A15.  Water inlet EV 

It allows the entry of water from the mains to the cold water deposit. It works at 230 Vac. 

This EV is only fitted to machines that are connected to the mains water supply. 
 

   unblock 

It has a security block system for cases where, for lime scale or any solids from the main

 

water  supply,  the  EV  does  not  close  properly.  This  system  activates  when  the  level  in  the 
residue bucket is excessively high.

 

To unblock the EV, switch off the water pressure from the mains. If this is not possible, tap the 
EV with a blunt object, for example an Allen key, on the inside of the hole on the top part of 
the EV as shown in the photograph. 
It you may also unblock the EV by tapping it with something like the handle of a screw driver. 

A16. Volumetric 

counter 

Its  function  is  to  measure  the  quantity  of  water  that  is  pumped  for  the  elaboration  of  the 
espresso coffee. 

 

A17. Water 

pump 

This element has the job of pumping water from the cold water deposit to the hot water boiler;

 

the cold water pushes the hot water towards the EVs for the instant products or towards the

 

infusion element for making espresso coffee. 

Summary of Contents for Tempo LE

Page 1: ...Technical information T E M P O Avda San Silvestre s n 31350 Peralta Navarra Spain Tel 34 948 709 709 www sat azkoyen com...

Page 2: ...ION OF COMPONENTS 2 1 PRINCIPLE COMPONENTS 2 2 HYDRAULIC CIRCUIT FOR ESPRESSO COFFEE 2 3 HYDRAULIC CIRCUIT FOR INSTANT PRODUCTS 3 INSTALLATION AND SWITCHING ON 3 1 UNPACKING 3 2 SWITCHING ON 3 3 ERROR...

Page 3: ...en 92 C and 96 C The water pressure at 8 kg cm The infusion time of the coffee between 20 and 28 seconds The volume of water in the infusion 40 ml Volume dosage this dosage system measures the volume...

Page 4: ...automatic function the press of a button is sufficient to elaborate a magnificent espresso coffee It grinds the coffee at the moment it is ordered Products that each machine can elaborate Tempo Coffe...

Page 5: ...ains voltage 230 Vac 50 Hz Heating element 230 Vac 50 Hz 1500 W Average daily consumption 3500 W Mains flex 3700 mm TEMPO espresso Voltage Power Length Mains voltage 230 Vac 50 Hz Heating element 230...

Page 6: ...ue liquids that the machine generates It has a capacity of 8 litres When it reaches a determined level a float device is activated to put the machine out of order until it is emptied A2 Coffee residue...

Page 7: ...nding how it is placed will vary the capacity of ground coffee the chamber will hold The spacer should be placed between the piston and its support when the dosage is set for 5 to 6 5 g of ground coff...

Page 8: ...ts position as it is held by the piston Before extracting the piston the black extraction button C7 should be pressed with the machine switched on On pressing the extraction button the infusion elemen...

Page 9: ...art of the beating process They control the hot water from the boiler to the beaters for the elaboration of the instant beverages They are fitted to a thermo compensated brass support that provides a...

Page 10: ...Coffee and decaffeinated Order of the EVs looking from the exterior of the machine A5 Ground coffee dosage element Situated on the side of the grinder its function is to measure the quantity of ground...

Page 11: ...he capacity is Series ME 1 3 kg Series LE 2 2 kg A7 Instant product hoppers The capacities are Series ME and MI 1 6 litres Series LE and LI 3 litres The approximate weight of the product is Capacity i...

Page 12: ...steps 1st Disconnect the wiring loom from the cup extractor board 2nd Unscrew the screws indicated in the photo 3rd Pull the extractors upwards until freeing them from the clips in the support screw W...

Page 13: ...ion button F9 Cup presence photocells F10 Hopper position micro F11 Sugar and spoon extractor connector Cup extractor characteristics Cup container ME and MI Series LE LI and LFB Series Quantity 500 7...

Page 14: ...l connections for the infrared photocell terminals that are used to detect the cups are Spoon extractor characteristics Spoon container ME and MI Series LE Li and LFB Series Quantity 250 350 Standard...

Page 15: ...nication protocol The models in the TEMPO M range use a coin validator It is always exact amount no change given On the left of the door there is a space for the coin changer which is held with three...

Page 16: ...B communication protocol coin system G2 Conectors for communication executive protocol coin system A12 Coffee grinder It has the model M03 from Azkoyen installed although before they had the grinder f...

Page 17: ...requested beverage All the product selections have a red led diode that lights when the machine is elaborating that beverage There is a panel with a label of all the available products in the machine...

Page 18: ...ivates when the level in the residue bucket is excessively high To unblock the EV switch off the water pressure from the mains If this is not possible tap the EV with a blunt object for example an All...

Page 19: ...e 9 Kg cm The by pass is a small hole covered with a ball that is held in place by a spring This spring will hold a pressure of 9 Kg cm but over this pressure it compresses and allows the water to pas...

Page 20: ...stant beverages is heated in this deposit L1 1500 W heating element L2 Security thermostat 120 C L3 Temperature sensor PTC L4 Triac L5 Electrovalves The boiler is made of brass and does not need any d...

Page 21: ...ss through the coffee and was retained in the infusion element goes out through the third outlet to the residue bucket The water recedes back from the infusion element towards the third outlet because...

Page 22: ...e 10 w Maximum pressure of EVs 15 Kg cm Working temperature of EVs 10 C a 140 C Control of the heating element is done with a triac that is situated on the boiler support Always respect the position o...

Page 23: ...4 170 31 170 68 171 05 171 42 171 79 190 172 16 172 53 172 90 173 26 173 63 174 00 174 37 174 74 175 10 175 47 200 175 84 176 21 176 57 176 94 177 31 177 68 178 04 178 41 178 78 179 14 210 179 51 179...

Page 24: ...d vapour from the interior of the machine It works on 230 Vac Extractor A21 Transformer Technical characteristics Primary 230 Vac Secondary blue blue 24 Vac Secondary black black 230 Vac Power 96 w A2...

Page 25: ...for the transmission of 34 volts another two for 8 volts and the remaining two are used for the communication between boards The colour and the function of each of the wires are the following PIN 1 O...

Page 26: ...ectrovalves S8 Hot water boiler This model will only work when connected to a mains water supply with a minimum pressure of 2 kg cm The machine comes with a pressure regulator of 2 kg cm and this is t...

Page 27: ...usion reaches the cup from a lesser height than the height of the outlet tube of the infusion group and thus avoiding bubbles in the tea T1 Container for green tea Infusion T2 Instant tea beater T3 El...

Page 28: ...e d Never leave the machine exposed to the elements sun rain snow etc 3 2 SWITCHING ON Site the machine in its place and level it using the regulating feet 3 2 1 Water connection The machine can be us...

Page 29: ...d with a filter the minimum water pressure should be 1 Kg cm 3 2 2 Electrical connection The machine works with 230 Vac 50 Hz The installation must have An earthed socket A minimum power rating of 250...

Page 30: ...te soporte es el mismo para los dos modelos de monedero V1 Soporte conexiones V2 Soporte monedero 3 2 5 Filling the product containers To put products in the containers you should lift the cover of th...

Page 31: ...g process occur The cold water deposit fills up if it is empty The volumetric counter is tested and the boiler is filled with the EVs closed When the counter stops spinning the boiler is full Then the...

Page 32: ...LID Error in signal of coins 03 ERROR VALIDATOR Fault in the module of recuperation ERROR RECUPERATION 0E EAB Fault communication with the changer 11 EAR MDB Reply incorrect of the changer 02 ERROR CH...

Page 33: ...ROR 1 19 ELZ1 Fault in extraction grid type of ERROR 2 1A ELZ2 Fault in extraction grid type of ERROR 3 1B ELZ3 Fault detector product fault type 1 FAULT IDETECT 1C Fault in temperature 1D EJJ Fault i...

Page 34: ...ERROR ARM P SUGAR Arm not reached stirrer position 04 ERROR ARM P STIR Fault arm 3 faults without reset 64 EBI3 Fault system extractor of cups ERROR SYS COPS 65 EBM Error in the mfc of the cup hopper...

Page 35: ...4 it will show 200 Vac when the pump is working Motor of the infusion group It is measured on the infusion board on the connector J15 Between pins 1 and 3 it will show 220 Vac when the group is workin...

Page 36: ...usion group motor It is measured on the infusion board on the connector J9 Between pins 2 and 6 it will show 5 Vdc when the infusion group is in the coffee making position Between pins 2 and 6 it will...

Page 37: ...sence It is measured on the Cup Board on the connector J5 Between pins 6 and 7 it will show 5 Vdc when there are cups between the photocells Between pins 6 and 7 it will show 0 Vdc when there are no c...

Page 38: ...nse it under a tap to remove coffee particles Before replacing the group dry it with a cloth Beaters Remove the beaters the outlet tubes and the chamber from the machine and clean everything with a wa...

Page 39: ...delines below Move the group to the coffee cake extraction position Hold the group and the lever with one hand while loosening the filter screw with the other On replacing the screw it is recommended...

Page 40: ...tasks The tool is micro processor controlled and has a flash memory with a capacity to store at least 8 programme modules 100 configurations or a combination of both The tool is connected directly to...

Page 41: ...ty The mains connection cable has an earth wire as established in the electrical safety norm The boiler has a temperature sensor that controls the connection and disconnection of the heating element a...

Page 42: ...ments are in mm and the weights in Kg M A C H I N E Tempo Width X1 Height X2 Depth X3 Weight ME MI 600 1620 620 49 44 LE LI 600 1830 620 60 55 C A B I N E T Tempo Width X1 Height X2 Depth X3 Weight ME...

Page 43: ...1 10012 E 02 2006 43...

Reviews: