1ª 10012 - E 02 - 2006
29
Models LE and LI are prepared for connection to the mains water supply in the factory,
so no additional parts are necessary.
However, for models ME and MI, it is necessary to add: an electro valve for the
mains connection, a cold water deposit, a water level gauge and the connection hoses.
The reference of this connection kit that includes this set is 41511891-0.
Depending on the quality of the water, hardness, chlorine, bleach, etc, the connection should be
complemented with a filter.
If the machine is fitted with a filter, the minimum water pressure should be 1 Kg/cm².
3.2.2. Electrical
connection
The machine works with 230 Vac (50 Hz). The installation must have:
•
An earthed socket
•
A minimum power rating of 2500 w
•
The installation site must have a breaker switch and a good earth connection
3.2.3.
Connecting a Coin Validator (Ranges MI/ME)
The Tempo ME and Tempo MI models are factory prepared to install a coin validator, which can
be from Azkoyen or another manufacturer. The validator is not supplied with the machine.
The fitting of the validator is simple; it is clipped into the bracket.
The wiring loom for the validator is connected to JP8 on the MDP circuit board. The machine
only works with exact change.
Azkoyen A6 2i validator
Summary of Contents for Tempo LE