1ª 10012 - E 02 - 2006
39
Depending on the use of the machine
Ô
Piston filter
. Every 15,000 services, it is recommended to remove and clean it. If
necessary, it can be cleaned with a non metallic brush. If the holes are blocked, do
not introduce sharp objects into the holes to clean them. It is recommended to
replace the filter with a new one when is becomes blocked.
Ô
Infusion group filter
. Clean the infusion group filter at the same time as you clean
the piston filter. To remove the filter without damaging it, follow the guidelines
below: Move the group to the coffee cake extraction position. Hold the group and
the lever with one hand while loosening the filter screw with the other. On replacing
the screw it is recommended to use Loctite 243 or a similar product to keep it tight.
OK
NO
Ô
Piston seal
. Substitute every 30,000 services
Ô
Group seals
. Substitute every 60,000 services. To get to these it is necessary to
remove the group filter. They are reachable by following the explanation below
.
1. Remove the filter holder and the group filter as shown above.
2. Press the clips (one on each side) indicated in the following photo until the part
is released at the gaskets.
3. After replacing the gaskets, fit the cover and gaskets back on the group.
Summary of Contents for Tempo LE
Page 43: ...1 10012 E 02 2006 43...