24
Chapter 5. SETTING AND OPERATION
Func
Name
Settings
Factory
Description
No.
setting
C06
Alarm event
00: Alarm event (general)
00
An alarm event can be output from terminal
01: AL59 battery alarm
AL. If 00 is selected, the output is the same as
02: AL40 over range
when 14 is selected in
C03
. The “AL“ LED
does not depend on the alarm event selected.
It lights up regardless of the kind of alarm.
C07
Event standby
00: Disabled
00
If 02 or 05 is selected in
C03
, the event
01: Enabled
standby will operate until the instantaneous
flow rate event setting is exceeded once after
power is turned on.
C08
Gas type
00: Air, nitrogen (fixed)
00
C 10
Operating
00: [No correction]
00
If the operating pressure is high, this function
pressure
01: [Direction 2] 0.5 MPa min.
is used to correct the pressure dependence
(correction for
02: [Direction 3] 0.5 MPa min.
due to pipe direction. For [Position 1] or
pipe direction)
[Position 4], select [00: No correction]
regardless of the operating pressure. For
[Position 2] or [Position 3], select [00: No
correction] if the operating pressure is less
than 0.5 MPa.
C 1 1
Reference
00 to 35
°
C (every 1
°
C)
00
If the setting is changed, the peak value and
temperature
the lowest value are reset.
*1: If you change the flow rate engineering unit, affix the appropriate unit label (included with the MCF) on top of the
current label.
*2: Minimum unit
MCF0080/0150/0151/0250: 10 L/pulse (0.01 m
3
/pulse, 0.01 kg/pulse)
MCF0400/0500: 100 L/pulse (0.1 m
3
/pulse, 0.1 kg/pulse)