Chapter 2.
PART NAMES AND FUNCTIONS
4
■
Parts name and functions
Flow rate display:
This 7-segment LED indicates instantaneous flow rate or inte-
grated flow amount. For the integrated flow, the first 4 digits
and last 5 digits are displayed separately. The 7-segment dis-
play also indicates settings in setting mode and alarm codes
when an alarm occurs.
LED lamp:
[L/min]
Lights up while instantaneous flow rate is indicated.
[L]
Lights up while integrated flow is indicated.
[EV]
Synchronized with event output
[AL]
Lights up when an alarm occurs
Keys:
[mode]
Changes the display or switches to setting mode, etc.
[
][
]
Increases/decreases the value of a setting, changes the display
mode, etc.
[enter]
Used to finalize function settings and parameter settings
Main flow path:
Connects to pipes. Inlet and outlet are marked.
Measurement module: Removable for maintenance. Can be changed with a new one
for the
MCF0250
,
MCF0400
and
MCF0500
.
Display unit:
Can be rotated in a plane parallel to the flow path. Rotates
180° clockwise and 90° counterclockwise, for viewing from
any direction.
Connector:
Provides the power and signal connections.
Bolts:
Fasten the measurement module in the main flow path.
Display unit
Connector
Outlet
Inlet
Measurement module
Flow rate display
Bolts
Main flow path
mode
enter
AL
EV
L
L/min
MCF