Azbil Infilex BC WY5610 Specifications & Instructions Download Page 2

AB-7163 

Safety Instructions 

Please read instructions carefully and use the product as specified in this manual.  Be sure to keep this manual near by for ready 
reference.  

Restrictions 

This product is targeted for general air conditioning.  Do not use this product in a situation where human life may be affected.  If 
this product is used in a clean room or a place where reliability or control accuracy is particularly required, please contact our
sales representative.  Azbil Corporation will not bear any responsibility for the results produced by the operators. 

 

Warnings and Cautions 

 WARNING

 

Alerts users that improper handling may cause death or serious injury. 

 CAUTION

 

Alerts users that improper handling may cause minor injury or material loss. 

 

Signs 

 

Alerts users possible hazardous conditions caused by erroneous operation or erroneous use. The symbol inside 

 

indicates the specific type of danger.  
(For example, the sign on the left warns of the risk of electric shock.) 

 

Notifies users that specific actions are prohibited to prevent possible danger. The symbol inside 

 graphically 

indicates the prohibited action.  
(For example, the sign on the left notifies that disassembly is prohibited.)  

 

Instructs users to carry out a specific obligatory action to prevent possible danger. The symbol inside 

graphically 

indicates the actual action to be carried out.   
(For example, the sign on the left indicates general instructions.) 

 

 WARNING  

 

Before wiring, be sure to turn off the power to the product. 
Failure to do so might cause electric shock. 

 

Be sure to ground the product with ground resistance of less than 100 

Improper grounding might cause electric shock or malfunction. 

 

Detach the terminal cover only when wiring the product.  Before detaching the terminal cover, be sure to turn off the 
power to the product and all the connected devices.  After wiring, be sure to reattach the terminal cover.   
Failure to do so might cause electric shock. 

 

Before replacing the unit, be sure to turn off the power to the unit.   
Failure to do so might cause electric shock. 

 

Install this product in a location out of reach of unauthorized people. (e.g. Inside of the control panel) 
Failure to do so might cause electric shock. 

 

 

 CAUTION 

(1/2)

 

Use the product under the operating conditions (temperature, humidity, power, vibration, shock, mounting direction, 
atmospheric condition, etc.) as listed in the specifications.  
Failure to do so might cause fire or device failure. 

 

Use the product within the rated operating ranges as listed in the specifications. 
Failure to do so might cause device failure. 

 

Installation and wiring must be performed by qualified personnel in accordance with all applicable safety standards.

 

All wiring must comply with applicable codes and ordinances. 

 

Take anti-lightening measures based on regional and building characteristics. 
Lightening might cause fire or critical damage to the products without the anti-lightening measures. 

 

Take anti-noise measures if the product is installed in a location near electric noise sources. 
Failure to do so might cause malfunction or device failure. 

 

Summary of Contents for Infilex BC WY5610

Page 1: ...ler Infilex BC is integrated in the BACnet IP network Compact design Small size body allows free installation in a desired place I O module configurations Input and output types are selectable and the...

Page 2: ...wiring be sure to turn off the power to the product Failure to do so might cause electric shock Be sure to ground the product with ground resistance of less than 100 Improper grounding might cause el...

Page 3: ...will not contact the connector Do not block the ventilation holes of this product Be sure to peel off the protective sheet after installation and wiring Doing so might cause fire or device failure Af...

Page 4: ...dition to the I O modules UT module and or integral type Operator Panel may be connected Figure 2 System configuration example Infilex BC Models WY5610W0000 and WY5611W0000 integrated into savic net F...

Page 5: ...RY50XX Order Number of Infilex BC Model WY5610W0010 control unit and Model WY5611W0000 I O control unit Order number Description 83171682 Infilex BC 101 One control unit and one I O control unit 103 O...

Page 6: ...M3 screw terminals 7 62 mm pitch between terminals Terminals connection Expansion bus communication Screwless push in terminals Wiring specifications I O control unit Item Wiring Wiring length Condit...

Page 7: ...This product complies with the following Electromagnetic Compatibility EMC and the Low Voltage Directive LVD EMC EN61326 1 Class A Table 2 For use in an industrial electromagnetic environment LVD EN61...

Page 8: ...AB 7163 8 Dimensions Figure 4 Dimensions mm 60 90 140...

Page 9: ...ex BC I O control unit At this time hold the male connector with the mark facing left and insert it as the mark points to the mark on the Infilex BC I O control unit Connection of Data Setter Model QY...

Page 10: ...ilex BC I O control unit with the modules varies depending on the number of the modules I O modules UT module and or integral type Operator Panel to be assembled Width of Infilex BC I O control unit O...

Page 11: ...ike connected to Infilex BC I O control unit so as not to hide LED Data Setter connector mark S1 switch battery holder or indication tag as shown in Fig 8 Make sure there is no slack in the wires from...

Page 12: ...oduct is always in use in ON state Replace the lithium battery with the power ON If the product has never or hardly been operated in OFF state for a year replace the lithium battery before the product...

Page 13: ...eral tens of seconds are required for the product normal operation after the power is turned on During this time the red LED ERR1 major failure on the front lights up indicating major failure temporar...

Page 14: ...AB 7163 14 Blank page added for editing purpose...

Page 15: ...AB 7163 15 Blank page added for editing purpose...

Page 16: ...t is a registered trademark of American Society of Heating Refrigerating and Air Conditioning Engineers ASHRAE KPEV is a registered trademark of Furukawa Electric Co Ltd in Japan Specifications are su...

Reviews: