Operation and Mounting

To activate the device, plug it into a mains socket. Once it's connected to an active power source, it will turn
on automatically. 

During startup, ‘AYRA’ will be shown on the display, which means the device is not ready to be operated.
Once the device has fully started up, it will jump to the last-used mode. Operation modes and other settings
shown on the display can now be adjusted or changed by means of the menu buttons. 

The device has no automatic DMX signal detection. If you want to use the device in DMX mode, manually
select  DMX  mode  and  optionally  change  the  starting address. For new devices, this will normally be DMX
address 001. Of course, you can change the DMX address via the display using the menu buttons.

Using  the  display  and  the  menu  buttons,  you  can  adjust  the  functions  and  settings  of  the  device.  Press
'Enter' to confirm an adjustment or select a function, use ‘Up’ and ‘Down’ to change amounts and ‘Menu’ to
go back to the menu. By holding the ‘Menu’ button down for 2 seconds after saving a specific setting, the
device will return to operation mode and adopt the setting. This will also be done after any changes in the
operation  mode  or  DMX  address.  This  operation  is  not  always  necessary,  considering  the  device
automatically does this after a new setting is confirmed. 

The menu contains the following options and functions.

Display

Mode

Function

A00X

DMX Address Configuration

Address A001 … A512

C000

Stand-Alone Selection

CD00-CD99 (0-100% Dimmer)
CF00-CF99 (Strobe off-slow-fast)

CN0X

Quick Stand-Alone Selection

CN01 100% Output level
CN02 66% Output level
CN03 33% Output level

AUTO

Automatic Program

AU00-AU099 (Slow-Fast)

SLAV

Slave Mode

‘Enter’ will automatically set the device as slave. 
If not set to slave, the device will operate as 
Master.

SOUN

Sound-Controlled Mode with 
adjustable sensitivity

S000-S099 (Not sensitive – Very sensitive)

1CH / 2CH

DMX Channel Mode Selection

1CH = 1-Channel DMX-mode
2CH = 2-Channel DMX-mode

You'll find an explanation of the various functions below:

ADDR: 

With this function, you can determine the DMX start address of the device. Set it channel 001, and 

the device will read DMX channel 1. Set it to channel 003, then the device will read DMX channel 3, etc.

C000:

  This  device  can  be  used  as  a  stand-alone  unit  and  thanks  to  the  possibility  to  separately  set  the

dimmer intensity and stroboscobe speed, you can decide how you want the device to behave within your set-
up. Separately adjust the dimmer and flashing intensity. 

AUTO:

This  device  features  an  automatic  show  mode.  This  demo  mode  shows  different  programs  and

effects. The speed setting is adjustable.

SLAV:

The Master-Slave mode is designed to sync multiple devices. A copy of the internal program is sent

to the daisy-chained devices so that each one projects the same effect. The master-slave function works by
means of standard 3-pin XLR cables. The only difference is that the first device in the chain does not receive
DMX input. In Slave 1 mode, the device will copy the exact signal directly from the Master.

 

The information in this user manual is subject to change at any time without notice.

Version: 1.0

Date of creation and author's initials:07-10-2019 RV

Revision date and author's initials: -

Summary of Contents for 9000-0051-4484

Page 1: ...ED Blacklight Bar User Manual The information in this user manual is subject to change at any time without notice Version 1 0 Date of creation and author s initials 07 10 2019 RV Revision date and aut...

Page 2: ...LED Brick does not function properly or if you have any issues while operating it please remove the plug from the power socket and contact your dealer for assistance Box contents Ayra UV LED Brick Arm...

Page 3: ...ve any cables lying around The device should not be opened up and any hardware or software that may be present should not be modified To achieve optimal performance inputs on the device should not be...

Page 4: ...hen installing and operating the device The user should become familiar with the functions of this device before using it Should the device not be used in the manner described in this user manual dama...

Page 5: ...that this product meets the European norms and requirements to which it must legally conform CE The CE logo indicates that this product meets the European norms and requirements to which it must legal...

Page 6: ...ower input with fuse holder 5 LED display with menu buttons 6 DMX input via 3 pins XLR 7 DMX output via 3 pins XLR The information in this user manual is subject to change at any time without notice V...

Page 7: ...fast CN0X Quick Stand Alone Selection CN01 100 Output level CN02 66 Output level CN03 33 Output level AUTO Automatic Program AU00 AU099 Slow Fast SLAV Slave Mode Enter will automatically set the devi...

Page 8: ...ype so they all function a specific way This way you can coordinate your light show by having multiple separate devices moving the same way instead of all different directions which can be chaotic Bas...

Page 9: ...nd the UV LED Brick you will need to attach a safety cable to the armature This is not included but is available at your local dealer The UV LED Brick is equipped with an eyelet for hooking a safety c...

Page 10: ...ossible data reflections Data reflections can cause strange behaviour in DMX controlled devices DMX terminators are sold separately but you may yourself decide to solder a 120 Ohm resistor between the...

Page 11: ...he DMX polarity switch on the DMX controller The device is not reacting there is no DMX signal indication Make sure the XLR cables are connected properly and are not defective Replace if necessary The...

Page 12: ...e is set The operating mode can not be changed The device is in Slave mode If the device is in Slave mode it will wait for a master signal unless there is a DMX signal present Set the device to Master...

Page 13: ...output via IEC C13 Fuse F3AL 250V To be used in environmental temperature 0 C 40 C Maximum housing temperature during normal use 51 C Fitted with ventilation slits Power supply 100 240V AC 50 60 Hz po...

Reviews: