8.5 PROGRAMMABLE INPUTS
AE-Lift has extra 3 programmable inputs (I1,I2,I3). Functions of inputs are listed in Table 8.5.
Table 8.5 Definitions of Programmable Inputs
INPUT CODE
FUNCTION
DEFINITION
00
___
No function
01
MCF
MC CONTROL:
Feedback check of motor contactors. Device not drive
motor until activation of this input. If input is not activated during [T01]
period, then system reports “Error 16-Contactor Error”. Connection
diagram of contacts are drawn in Figure 8.17.
02
BRF
BRAKE CONTROL:
Feedback check of mechanical brake control contacts.
Device not drive motor until activation of this input. If input is not
activated during [T02] period, then system reports “Error 17-Brake
Error”. Connection diagram of contacts are drawn in Figure 8.17.
8.6 PROGRAMMABLE OUTPUTS
AE-Lift has extra 2 programmable outputs (O1 and O2). Informations about contacts are listed in Table
4.3 and functions are listed in Table 8.6.
Table 8.6 Programmable Output Codes and Definitions
OUTPUT
CODE
FUNCTION
DEFINITION
00
___
No function
01
STP
No motion in system
02
MTN
Motion in system
03
NLA
Output current is above noload current of motor
04
NLB
Output current is below noload current of motor
8.7 PASSWORD CHANGE PROCESS
AE-Lift has menu password protection feature. Factory default of password is 00000 which means
passive. Password activated by 5 digits value between 00001 and 65000. System warns you with
“PASSWORD CHANGED” after completion of password change process.
F/7.5.5.02.95 R:1
41
AE-LIFT
Figure 8.17 Brake and Contactor Feedback