51
AXIS 213 - Connection Module
Connection Module
The connection module is an optional accessory that connects to the camera and
provides the following connections:
• SERVER - for the connection to the AXIS 213
• AUDIO IN/OUT
• 2 Digital inputs
• 3 Relay outputs
• VIDEO IN
• VIDEO OUT
• RS-232C serial port
The connection module is configured and controlled via the camera’s user interface.
Notes:
• Use an electret microphone. The microphone will be powered by the module through a 9.4k
• Use amplified speakers only, stero or mono plug
AUDIO IN/OUT
1. Connect a microphone (not supplied) to the
AUDIO IN
socket.
2. Connect a loudspeaker (not supplied) to the
AUDIO OUT
socket (amplified
speakers only).
Inputs and outputs (I/Os)
The I/Os are used in applications for, e.g. event triggering, time lapse recording, alarm
notification via email, image storage to FTP locations.
•
Input
- e.g. a pushbutton. If the button is pressed, the
state
changes, and the
input will be active (shown under
Event Configuration > Port Status
).
•
Output
- e.g. an alarm device that can be activated from Output buttons on
the
Live View
page, or as an action for an
Event Type
.
If the alarm device is
activated,
the output will show as
active
(under
Event Configuration > Port
Status)
Connect to GND to activate or leave floating (unconnected) to deactivate.
Active output, electrical connection between A and B. Non active output, no connection
between A and B.
Imax=100mA, VMax=24V
I/O
Description
Alarm In 1,2
Alarm GND
Alarm Out
1A,1B;2A,2B;3A,3B
Ω