A795 User Guide: Programming Supplement
Chapter 4: Programming commands
81
Printer status (n = 1 or n = 49)
Bit Off/On
Hex
Decimal
Status for transmit status
0
Off
00
0
Paper present.
On
01
1
Paper exhausted.
1
Off
00
0
Cover closed.
On
02
2
Cover open.
2
Off
00
0
Paper present.
On
04
4
Paper exhausted.
3
-
-
-
Undefined.
4
Off
00
0
Not used. Fixed to off.
5
-
-
-
Undefined.
6
-
-
-
Undefined.
7
Off
00
0
Not used. Fixed to off.
Cash drawer status (n = 2 or n = 50)
Bit Off/On
Hex
Decimal
Status for transmit status
0
Off
00
0
One or both cash drawers
open.
On
01
1
Both cash drawers closed.
1
Off
00
0
One or both cash drawers
open.
On
02
2
Both cash drawers closed.
2
-
-
-
Undefined
3
-
-
-
Undefined
4
Off
00
0
Not used. Fixed to off.
5
-
-
-
Undefined.
6
-
-
-
Undefined.
7
Off
00
0
Not used. Fixed to off.
Flash memory user sector status (n = 4 or n = 52)
Bit Off/On
Hex
Decimal
Status for transmit status
0
-
-
-
Undefined. Fixed to off.
1
-
-
-
Undefined. Fixed to off.
2
Off
00
0
User data storage write
successful
On
04
4
User data storage write
failed, specified area not
erased.
3
Off
00
0
Flash logo area adequate,
definition stored
On
08
8
Flash logo area not
adequate
4
Off
00
0
Not used. Fixed to off.
5
Off
00
00
No thermal user-defined
characters written to flash.
On
20
32
Thermal user-defined
characters written to flash.
6
Off
00
0
Not used. Fixed to off.
7
-
-
-
Undefined.
Exceptions
When n is out of the specified range, the command is
ignored.