![Axel Falcon 35 Operating Manual Download Page 24](http://html1.mh-extra.com/html/axel/falcon-35/falcon-35_operating-manual_3036025024.webp)
FIRST INSTALLATION RECOMMENDATIONS
ENG
Page 24
12.3 FUSE REPLACEMENT
The power supply socket has an integral fuse drawer containing the AC power fuse and a spare, both of the
same value.
BEFORE REPLACING THE POWER FUSE, MAKE SURE YOU HAVE THE RIGHT TYPE
OF FUSE FOR THE VOLTAGE TO BE PROTECTED.
USING WRONG FUSE TYPE WILL RESULT IN INSUFFICIENT PROTECTION.
Make sure that the power is switched off and the power cable is disconnected from the equipment.
Open the fuse drawer using a small blade screwdriver.
Replace the fuse located at the inner position
Push the fuse socket back into the original position
12.4 REMOVING THE EQUIPMENT TOP COVER
A unique flexibility is offered, in order to satisfy the exact requirements of each installation. This is done by
setting internal jumper links and calibration trimmers which determine the operating levels and the signal
routing. Jumper links are accessed by removing the top cover. Thus, once installed the settings become
tamperproof.
To change any jumpers or set the voltage changeover you must remove the top cover of the unit to access
the main boards. Remove all screws holding the cover in place, then lift it off. Use care when working inside
the unit.
Perform the set-up under static control conditions. Static charges are likely to completely
destroy one or more of the CMOS semiconductors employed in the unit. Static damage will
not be covered under warranty.
Basic damage prevention consists of minimizing generation, discharging any accumulated
static charge on your body and preventing that discharge from being sent to or through any
electronic component.
Uninsulated dangerous voltage are inside the enclosure, voltage that may be sufficient to
constitute a risk of shock.
Always disconnect to AC Mains before removing the top cover