Page | 14
Turn on the power source. Within six seconds, press the “Program” (P2) button twice (located in the
battery compartment of the remote) and then press the “UP” Button once. If the direction did not
change then do the following:
Turn off the power source of the awning
Turn on the power source. Within six seconds, press the “Program” (P2) button twice (located in the
battery compartment of the remote) then press the “DOWN” Button once.
Add an additional Remote Control (transmitter
)
Turn off the power source of the awning
Turn on the power source. Press the “Program” (P2) button two times on the existing remote. Within six
seconds, press the “Program” (P2) button once on the additional remote control, then press “UP” button
once on the additional transmitter.
HOW TO ADJUST LIMIT CONTROLS ON YOUR MOTOR.
CAUTION: IMPROPER ADJUSTMENTS CAN CAUSE THE AWNING MOTOR TO BREAK.
MOTOR Model: AT45MRLimit Adjustment Control Operation
VERY IMPORTANT:
YOU MUST ADJUST THE CONTROLS FROM THE BOTTOM OF THE MOTOR
The motor has internal temperature cutoff switch. If the motor gets to hot it will stop working, it will start working
after 20 minutes or as soon as motor cools down. Do not worry, this motor has manual override option and you
can always open or close the awning manually by using the crank handle.
This motor has a limit control switch to control the extension and retraction of your unit. The limit adjustments
controls are in Red and White are located next to the electrical cord of the motor. In order to adjust the limit
controls you would need to insert the tool looks like wand to turn the controls either “clock wide” or “counter
clock wise”
LIMIT CONTROLS (WHEN YOU LOOK UP)