The instrument and the DUT will not be damaged if the diode is installed with the
incorrect orientation (i.e., with the anode and cathode reversed). However, incorrect
waveforms will be generated.
When closed, the lid is held is place by a magnetic latch. To open the lid, simply pull
upwards on the handle at the front of the lid.
Over time, the “lid pressure fin” may become worn down, resulting in poor DUT contact
with the spring pins. Four replacement fins are included with each AVX-TRR-ANB, for
this reason.
The AVX-TRR-ANB is still available, but the AVX-TRR-AXPOST or AVX-TRR-HPOST
are recommended as superior replacements.
AVX-TRR-
AXPOST
JIG
The AVX-TRR-AXPOST provides easy-to-use spring-loaded push-posts for axial
packages with body length of up to 0.25” (and diameters up to 0.5”), including DO-35,
DO-41 and Microsemi Axial Type E packages (0.185" x 0.135" body, max). Lead
bending is NOT required to insert these packages. Push down on the colored caps to
open the “claws” of each post and insert a lead. Release the caps to engage the spring-
loaded hold.