Front Panel Control - EDID
This matrix has 29 factory defined EDID settings. It also has 3 user defined EDID memories. The user
EDID memories are independent to each input and can be set differently. The user defined EDID can be
uploaded using the free PC Control software or RS-232. In addition, you can choose to read the EDID from
the desired output and the captured EDID will automatically store and overwrite the EDID in “USER EDID 1”
and will be applied to the selected source.
·
Use the arrow keys to highlight EDID then press OK to enter the EDID management menu.
·
Use the Left/Right arrow to select one of the 4 INPUTS, and press OK.
·
The EDID Status will turn red, now you can use the UP/DOWN arrows to change the EDID.
·
Once the desired EDID is selected, press the OK button to set.
NOTE: See page[s] 18 and 37 for full EDID list