20
DC variants: Wiring instructions-Data cable
The data cable can be brought into the junction box via the lower cable glands on either
the left or right-hand side
•
Connect the ISO-REF conductor from the control unit to the upper socket on terminal
block 3 (highlighted in yellow)
•
Continue the daisy chain from the lower socket (highlighted in red) on terminal block 3
to the next light
•
Connect the ISO-DIG-IN/OUT conductor from the control unit to the upper socket on
terminal block 4 (highlighted in yellow)
•
Continue the daisy chain from the lower socket (highlighted in red) on terminal block 4
to the next light
•
Connect the ISO-GND conductor from the control unit to the upper socket on terminal
block 5 (highlighted in yellow)
•
Continue the daisy chain from the lower socket (highlighted in red) on terminal block 5
to the next light
•
Connect the AN-IN conductor from the control unit to the upper socket on terminal
block 6 (highlighted in yellow)
•
Continue the daisy chain from the lower socket (highlighted in red) on terminal block 6
to the next light
•
Connect the AN GND conductor from the control unit to the upper socket on terminal
block 7 (highlighted in yellow)
•
Continue the daisy chain from the lower socket (highlighted in red) on terminal block 7
to the next light