Timeout Duration
This menu is only visible when the timeout Mode is enabled. This menu is used to select the timeout
duration, the time before the LED intensity reverts back to its LOW intensity state. The timeout duration
can be set from 1 minute to 60 minutes.
LED Bank Setup
All Avlite ALS systems can have the option of having the lights built with multiple colours, in different LED
banks. This can allow a runway to be changed from Visible to I/R at the press of a button.
The options include
VISIBLE & IR.
Note:
this menu will not be enabled if the selected operational mode is
STANDBY
Battery Diagnostic
Default = Disable
This feature can be used to check the battery voltage in every light in the ALS. The command can be
sent any time and it will not affect the current state of the light. If the light is in STANDBY mode the light
will turn on as shown below and revert to STANDBY mode after the diagnostic has been completed.
• If the battery voltage is within operational range the light will turn off for 1 second, flash once, then
turn off for 1 second.
• If the battery voltage is low the light with turn off for 1 second, flash twice, then turn off for 1 second.
Sending Commands
Every time the SEND button is pressed a command is sent containing all the current settings in the Radio
Controller.
The SEND button can be used after changing one setting or after changing multiple settings.
For further information see section under “How does the System Work”.