Figure 10 - Voltage Control Board Adjustments
9.2.5.2.
VOLTAGE CONTROL - See [
Figure 10
]
9.2.5.2.1.
R11, FLOAT VOLTAGE:
•
Connect a CAL-100 Calibrator or a power supply
capable of producing at least 10V (very little current
required) to the CAL (-) and CAL (COMMON) test
points. The positive lead to COMMON and the
negative lead to CAL (-).
•
Set the calibrator/power supply to 2.70V to simulate
a battery that has 27.0V.
•
NOTE: The Calibrator voltage is 1/10 of the
simulated battery voltage.
•
Connect a battery to the Charger-Analyzer.
•
Set the Voltage Control Mode Switch to CV
(Constant Voltage)
•
Program for 10A of Topping current.
•
Enter 24 in the cell selector (nominal battery
voltage).
•
Start the Charger-Analyzer in Single rate. The
current will rise to the programmed 10A.
•
Increase the power supply voltage towards 2.8V and
observe the current.
•
The charging current will begin to decrease at about
2.75V and should reach zero as the voltage is
advanced to 2.8V.
•
NOTE: Ignore the actual battery voltage. The Float
voltage control circuit is responding to the simulated
battery voltage as provided by the power supply
.
Summary of Contents for Supercharger 60
Page 7: ...Operator Manual Supercharger 60 R3 0 Page 7 of 62 Figure 1 Block Diagram ...
Page 20: ...Operator Manual Supercharger 60 R3 0 Page 20 of 62 Figure 2 Front Panel ...
Page 44: ...Operator Manual Supercharger 60 R3 0 Page 44 of 62 Figure 6 Meters Board Adjustments ...
Page 52: ...Operator Manual Supercharger 60 R3 0 Page 52 of 62 Figure 11 Circuit Board Sequence ...
Page 57: ...Operator Manual Supercharger 60 R3 0 Page 57 of 62 Figure 13 Location of Current Limiters ...
Page 58: ...Operator Manual Supercharger 60 R3 0 Page 58 of 62 Figure 14 Power Block Diagram ...