![Avix Supercharger 60 Operator'S Manual Download Page 11](http://html.mh-extra.com/html/avix/supercharger-60/supercharger-60_operators-manual_3032464011.webp)
Operator Manual, Supercharger 60
R3.0
Page 11 of 62
2.4
Discharge
NOTE 1: Do not place batteries on the Temp-Plate during discharge. Due to the normal
heating of the battery a false Overtemp may be generated later during the charge
process.
NOTE 2: Do not attempt to discharge with the voltage mode selector in the Float or Peak
voltage modes. Voltage and current faults will occur depending on the battery voltage
and the cell selector setting.
2.4.1.
Number of Cells
2.4.1.1.
Enter the number of cells.
2.4.1.2.
Ignore this step if FULL DISCHARGE is to be selected.
2.4.2.
Total Time
2.4.2.1.
Enter the TOTAL TIME.
2.4.2.2.
Verify that the Timer Speed is consistent with the required elapsed
time.
2.4.2.3.
Enter the DISCHARGE CURRENT.
2.4.2.4.
Depress the Blue button for DISCHARGE with automatic cut-off
(ANALYSIS), or the RED button for FULL DISCHARGE (DEEP
CYCLE).
2.4.2.5.
DISCHARGE will terminate automatically (CYCLE END) when the
(TOTAL) time selected is reached or (CAPACITY FAILURE) if the
BATTERY voltage reaches the equivalent of ONE VOLT per CELL
prior to the selected time.
2.4.2.6.
NOTE: Battery voltage is ignored during Full Discharge.
2.4.2.7.
Discharge will terminate as a FAULT if the MONITOR CIRCUIT
detects:
•
An overheating of the discharge transistors (OVERHEAT
FAULT).
•
That the discharge current differs from the programmed value by
more than one AMP (CURRENT FAULT).
•
That the programmed current exceeds 30A for a battery voltage in
excess of 32V.
Summary of Contents for Supercharger 60
Page 7: ...Operator Manual Supercharger 60 R3 0 Page 7 of 62 Figure 1 Block Diagram ...
Page 20: ...Operator Manual Supercharger 60 R3 0 Page 20 of 62 Figure 2 Front Panel ...
Page 44: ...Operator Manual Supercharger 60 R3 0 Page 44 of 62 Figure 6 Meters Board Adjustments ...
Page 52: ...Operator Manual Supercharger 60 R3 0 Page 52 of 62 Figure 11 Circuit Board Sequence ...
Page 57: ...Operator Manual Supercharger 60 R3 0 Page 57 of 62 Figure 13 Location of Current Limiters ...
Page 58: ...Operator Manual Supercharger 60 R3 0 Page 58 of 62 Figure 14 Power Block Diagram ...