NOTE 3: Insert an external shunt/ammeter in series with any of the
battery leads (Use the Single Cell adaptor to facilitate the
connection or simply use the CAL-100 which is a calibrator
designed specifically to test and certify Charger-Analyzer Battery
Charger-Analyzers.
•
NOTE 4: The charge output current wave is in the form of short
pulses (at twice the line frequency). The use of clamp-on meters
and moving magnet meters will yield erroneous readings. Verify in
discharge (pure DC) if better meters are not available.
9.2.2.
VOLTMETER.
9.2.2.1.
ZERO: No zero adjustments.
9.2.2.2.
SCALE:
•
This meter has a full scale of 1.999 volts, but an attenuator on the
board converts it to a full scale of 1.999, 19.99 or 199.9 volts, as
selected by the DPM selector switch.
•
Verify and calibrate using a voltage source (Power Supply or
CAL-100, as a battery voltage simulator) between 10 and 20 volts
in the "EXTERNAL 20V" position.
•
Adjust R17 for a reading within " 0.01V of the reference voltmeter.
•
NOTE: individual scales cannot be adjusted.
Summary of Contents for Supercharger 60
Page 7: ...Operator Manual Supercharger 60 R3 0 Page 7 of 62 Figure 1 Block Diagram ...
Page 20: ...Operator Manual Supercharger 60 R3 0 Page 20 of 62 Figure 2 Front Panel ...
Page 44: ...Operator Manual Supercharger 60 R3 0 Page 44 of 62 Figure 6 Meters Board Adjustments ...
Page 52: ...Operator Manual Supercharger 60 R3 0 Page 52 of 62 Figure 11 Circuit Board Sequence ...
Page 57: ...Operator Manual Supercharger 60 R3 0 Page 57 of 62 Figure 13 Location of Current Limiters ...
Page 58: ...Operator Manual Supercharger 60 R3 0 Page 58 of 62 Figure 14 Power Block Diagram ...