ZM305 GTN Inbound-Outbound User Instructions
43
7.1 Setpoint
13.
Key in the value you want the output to activate above or below and press
ZERO
to accept the value.
Edit X
is displayed. Go to step
18
.
14.
Key in a value for
outX Lo
and press
ZERO
to accept …
outX Lo
is displayed.
15.
Press
UNITS
…
outX Hi
is displayed.
16.
Key in a value for
outX Hi
and press
ZERO
to accept …
outX Hi
is displayed.
17.
Press the
TARE
key …
Edit X
is displayed.
18.
Press the
TARE
key …
OutX
is displayed.
19.
Repeat steps
6
through
17
for
out2
and
out3
.
Inputs
Setpoint
Edit
Annun
Out
In
20.
Press
UNITS
when finished …
in1
is displayed. This stands for input 1. Use this to assign a function to
input 1 when an external switch is tripped. Default choice is
nonE
. The
choices are listed in
Figure 7.1
.
21.
From
in1
, press
SELECT
…
The current choice is displayed.
22.
Press
UNITS
to scroll through the choices and when your choice is displayed,
press
ZERO
to accept …
in1
is displayed.
23.
Press
UNITS
…
in2
is displayed.
24.
Repeat steps
21
through
23
for
in2
and
in3
.
25.
Press
TARE
when finished …
Edit
is displayed.
Inputs are enabled (ON) in a separate password protected menu. Some input choices