22
ZM305 GTN Inbound-Outbound User Instructions
Truck In/Out Operation
4.
Press
SELECT
…
The current Mode setting for the selected Output is displayed. The Mode
settings are listed below:
Act AbV
(default)
The output is active when the weight is above the
set value
Act bEL
The output is active when the weight is below the
set value
Act in
The output is active when the weight is inside of
the low and high set values
Act out
The output is active when the weight is outside of
the low and high set values
5.
Press
UNITS
or
to scroll through the choices shown above and then
press
ZERO
to accept the displayed Mode …
ModE X
is displayed.
6.
Press
UNITS
…
Edit X
is displayed. Set the value or values for the output under this
menu item.
7.
Press
SELECT
…
If you selected Mode
Act AbV
or
Act bEL
, a value entry screen is
displayed. Go to step
8
.
If you selected Mode
Act in
or
Act out
,
outX Lo
is displayed. This is one
of two value entry screens under
Edit X
. Go to step
9
.
8.
Key in a value the you want the output to activate above or below and press
ZERO
to accept the value.
Edit X
is displayed. Go to step
13
.
9.
Key in a value for
outX Lo
and press
ZERO
to accept …
outX Lo
is displayed.
10.
Press
UNITS
…
outX Hi
is displayed.
11.
Key in a value for
outX Hi
and press
ZERO
to accept …
outX Hi
is displayed.
12.
Press the
TARE
key …
Edit X
is displayed.
13.
Press the
TARE
key …
OutX
is displayed.
14.
Repeat steps
1
through
12
for
out2
and
out3
.
15.
Press
TARE
repeatedly to return to normal weighing mode with the setpoints
active.