18
ZM305 GTN Inbound-Outbound User Instructions
Truck In/Out Operation
3.2 Truck inbound-outbound operations
This indicator is designed to streamline the collecting of net weights from inbound and
outbound trucks. Use the
IN/OUT
key for transactions involving non-Fleet trucks. Use
the
FLEET
key for transactions involving Fleet Trucks that already have a stored tare
weight.
Until a Truck ID is entered the
key can be used for General weighing
transactions using the configured protocols. Once a Truck ID is entered the
key
will be associated with an Inbound or Outbound Ticket transaction.
3.2.1 IN/OUT key operation
1.
Press the
IN/OUT
key to perform a Truck Inbound or Outbound transaction. The
indicator must be in the gross weight mode or the message
cAnt
is displayed
momentarily.
truckId
is briefly displayed followed by the last active truck ID (last digit
is flashing)
2.
Press
ZERO
to accept the displayed ID…
OR
Use the numeric keypad to enter a different Truck ID and press
ZERO
to
accept …
When entering the Truck ID:
l
If the ID is already in use as a Fleet truck, the display will show
cAnt
then
FLEEtId
and then return to the weight screen.
l
If the ID does not have a stored Inbound transaction the display will
show
inbnd
(proceed to step
1
)
l
If the ID has a stored Inbound transaction the display will show
outbnd
(proceed to step
2
)
Inbound transaction (1st weighment)
1.
When the truck is on the scale and weight is stable press
to store and
print the Inbound transaction. Below is an example of an Inbound ticket:
In Date 07-21-2014
In Time 1:21 PM
Truck ID 123
In Weight 18580 lb