55
S232 Command Table
Visca Command Table
Command Set
Command
Command Packet
Comments
IF_Clear
8x 01 00 01 FF
x = Cam address
IF_Clear(broadcast)
88 01 00 01 FF
CAM_Power
On
8x 01 04 00 02 FF
*RS-232 supported, UDP not
supported
Off
8x 01 04 00 03 FF
CAM_Zoom
Stop
8x 01 04 07 00 FF
Tele(Variable) 8x 01 04 07 2p FF
p=0 (Low) to 7 (High)
Wide(Variable) 8x 01 04 07 3p FF
Direct
8x 01 04 47 0Y 0Y 0Y 0Y FF
0xYYYY = zoom pos
CAM_Focus
Far(Variable) 8x 01 04 08 2P FF
p=0~F
Near(Variable) 8x 01 04 08 3P FF
p=0~F
Auto Focus
8x 01 04 38 02 FF
Manual Focus 8x 01 04 38 03 FF
One Push
8x 01 04 18 01 FF
CAM_WB
Auto
8x 01 04 35 00 FF
Normal Auto
One Push WB 8x 01 04 35 03 FF
One Push WB mode
Manual
8x 01 04 35 05 FF
Manual Control mode
One Push
8x 01 04 10 05 FF
One Push WB Trigger
CAM_RGain
Up
8x 01 04 03 02 FF
Manual Control of R Gain
Down
8x 01 04 03 03 FF
CAM_Bgain
Up
8x 01 04 04 02 FF
Manual Control of B Gain