Aventics R412022854 Operating Instructions Manual Download Page 6

General safety instructions

W

Observe the regulations for accident prevention and 
environmental protection in the country where the product 
is used and at the workplace.

W

Do not modify or convert the device.

W

Only use the device within the performance range provided 
in the technical data.

W

The warranty will not apply if the product is incorrectly 
assembled.

W

Do not place any improper mechanical loads on the product 
under any circumstances.

Safety instructions related to the product 
and technology

On installation

W

Make sure the relevant system component is not under 
pressure or voltage before assembling the product or when 
connecting and disconnecting plugs. 

During operation

W

Only commission the sensor after it has been completely 
assembled, as well as correctly connected and tested.

W

Observe the operating conditions and data printed on the 
relevant sensor or stated on its rating plate.

W

Do not disconnect plugs or lines when the sensor is under 
voltage.

ATEX – information on explosion protection

ST6-ATEX sensors are certified and labeled according to the 
enclosed declaration of conformity.

They can be used

W

with gases, mists, or vapors in zone 2

W

with flammable dust particles in zone 22

Explanations concerning identification

Due to the small size of the sensor, the ATEX identification 
is located on a cable flag. 

Year of manufacture of the sensor: The first two digits 
in the 5-digit date code on the rating plate indicate the year 
and the last two digits indicate the week.

II 3G Ex nA IIC T4 Gc X

II 3D Ex tc IIIC T135°C Dc X

The device will lose its Ex approval if these instructions are not 
complied with!

3

Delivery Contents

W

1x ST6-ATEX sensor

W

1 set of operating instructions (R412024085)

Variants with 

M8

 and 

M12

 plugs:

W

Cable with plug and removal protection clip

4

About This Product

The ST6-ATEX sensor is used to detect magnetic fields in explosive 
areas.

Product identification

O

Observe the product information on the product and 
packaging.

5

Assembly and Commissioning

Sensor porting configuration 

O

Observe the Ex guidelines as per EN 60079-14.

O

The installation of electrical devices must be carried out 
in accordance with applicable national regulations and 
performed or supervised by an electrical specialist 
(in compliance with TRBS 1203 or equivalent).

O

Compare the information on the device with the information 
in the operating instructions before installation.

WARNING

Danger of an ignition source due to impermissible operating 

conditions, connections, and parameters!

Operating the sensor under impermissible operating conditions 
can result in an explosion.

O

Observe the permissible operating conditions, in particular 

the ambient temperature and the mechanical protection 

for the device. 

O

The ST6-ATEX sensor is only intended for complete 

installation in suitable T-slots.

O

Note the limited temperature range for ATEX conditions. 

O

Do not disconnect the plug connectors and the connecting 

cable from the sensor if it is under voltage.

O

Only use approved 

M8

 and 

M12

 connecting cables from 

the AVENTICS GmbH product offering. 

O

Observe the relevant Ex guidelines for installation, 

maintenance, and repair, especially EN 60079-14.

1

4

3

+

R

L

BN

BU

BK

AVENTICS

 | ST6 | R412024085-BAL-001-AC | English

4

Summary of Contents for R412022854

Page 1: ...nes de servicio Bruksanvisning R412024085 2017 06 Replaces 2017 03 DE EN FR IT ES SV Sensor ATEX zertifiziert Sensor ATEX certified Capteur certifié ATEX Sensore certificato ATEX Sensor con certificación ATEX Sensor ATEX certifierad ST6 E II 3G Ex nA IIC T4 Gc X II 3D Ex tc IIIC T135 C Dc X ...

Page 2: ...Konformitätserklärung Declaration of Conformity Déclaration de conformité Dichiarazione di conformità Declaración de conformidad Konformitetsförklaring ...

Page 3: ...nannten Leistungsgrenzen ein O Setzen Sie den Sensor zum Erfassen von magnetischen Feldern in explosionsgefährdeten Bereichen ein Nicht bestimmungsgemäße Verwendung Als nicht bestimmungsgemäße Verwendung gilt wenn Sie den Sensor ST6 ATEX W außerhalb der Anwendungsgebiete verwenden die in dieser Anleitung genannt werden W unter Betriebsbedingungen verwenden die von den in dieser Anleitung beschrieb...

Page 4: ... Verbindungskabel nicht bei anliegender Spannung vom Sensor O Verwenden Sie nur freigegebene Verbindungskabel M8 und M12 aus dem Produktprogramm der AVENTICS GmbH O Beachten Sie bei Installation Wartung oder Reparatur die entsprechenden Ex Vorschriften insbesondere EN 60079 14 5 Montage und Inbetriebnahme Anschlussbild Sensor O Beachten Sie die Ex Vorschriften gemäß EN 60079 14 O Die elektrische I...

Page 5: ...eep these instructions in a location where they are accessible to all users at all times O Always include the relevant operating instructions when you pass the ST6 sensor on to third parties Intended use O The ST6 ATEX sensor is only intended for industrial applications O The pressure regulator may only be used within the limits listed in the technical data O The sensor is to be used to detect mag...

Page 6: ...Gc X II 3D Ex tc IIIC T135 C Dc X The device will lose its Ex approval if these instructions are not complied with 3 Delivery Contents W 1x ST6 ATEX sensor W 1 set of operating instructions R412024085 Variants with M8 and M12 plugs W Cable with plug and removal protection clip 4 About This Product The ST6 ATEX sensor is used to detect magnetic fields in explosive areas Product identification O Obs...

Page 7: ...ion dangereuse susceptible d entraîner des blessures graves ou mortelles si le danger n est pas évité ATTENTION Signale une situation dangereuse susceptible d entraîner des blessures légères à modérées si le danger n est pas évité En cas de non respect de cette information le produit ne livrera pas sa performance optimale 1 Fit the sensor into the T slot any mounting orientation 2 Install the sens...

Page 8: ...onter l appareil ou de le brancher ou débrancher Lors du fonctionnement W Ne mettre le capteur en service que lorsqu il est complètement monté correctement raccordé et après l avoir testé W Observer les conditions d utilisation et les données techniques indiquées sur les imprimés plaques signalétiques du capteur respectif W Ne débrancher aucune fiche ni aucun câble sous tension ATEX Remarques conc...

Page 9: ...N Risque de blessure en cas de montage sous pression et sous tension électrique Un montage sous pression et sous tension électrique peut entraîner des blessures O Avant le montage mettre toutes les parties pertinentes de l installation hors tension et hors pression 1 4 3 RL BN BU BK 7 Elimination O Eliminer le produit selon les dispositions nationales du pays concerné 8 Recherche et élimination de...

Page 10: ... evitata può provocare lesioni medie o leggere In caso di inosservanza di questa informazione il prodotto non può essere utilizzato in modo ottimale conoscenze delle disposizioni vigenti sono in grado di valutare i lavori commissionati individuare i possibili pericoli e adottare le misure di sicurezza adeguate Il personale specializzato deve rispettare le norme specifiche vigenti e possedere la qu...

Page 11: ...i tensione O Utilizzare solo cavi di collegamento autorizzati M8 e M12 nel programma prodotti AVENTICS GmbH O Durante l installazione la manutenzione o la riparazione attenersi assolutamente alle rispettive norme Ex in particolare EN 60079 14 1 4 3 RL BN BU BK 1 Montare il sensore nella scanalatura a T posizione di montaggio qualsiasi 2 Montare il sensore in posizione protetta meccanicamente e da ...

Page 12: ...o con las instrucciones de servicio Utilización conforme a las especificaciones O Haga uso del sensor ST6 ATEX únicamente en el ámbito industrial O Respete los límites de potencia mencionados en los datos técnicos O Utilice el sensor para registrar campos magnéticos en zonas con riesgo de explosión Utilización no conforme a las especificaciones Se considera que se realiza una utilización no confor...

Page 13: ...or por enchufe y el cable de unión si el sensor se encuentra bajo corriente O Utilice únicamente los cables de unión M8 y M12 homologados del programa de productos de AVENTICS GmbH O En los trabajos de instalación mantenimiento y reparación tenga en cuenta las correspondientes disposiciones sobre atmósferas explosivas en especial la norma EN 60079 14 3 Volumen de suministro W 1 sensor ST6 ATEX W 1...

Page 14: ... på ett säkert och fackmannamässigt sätt Ytterligare dokumentation Sensor ST6 ATEX är en systemkomponent O Observera även systemdokumentationen från systemtillverkaren Återgivning av information Säkerhetsföreskrifter I denna dokumentation står säkerhetsinformation före en handlingsföljd där det finns risk för person eller sakskador Säkerhetsanvisningar är uppställda enligt följande Varningstecknen...

Page 15: ...änds W utanför det användningsområde som denna bruksanvisning anger W under driftsvillkor som avviker från dem som anges i denna bruksanvisning Förkunskapskrav Montering och driftstart kräver grundläggande elektriska och pneumatiska kunskaper Montering och driftstart får därför endast utföras av en fackman inom el och pneumatik eller av en person under ledning och uppsikt av en sådan person Med fa...

Page 16: ...ensorn vid störningar eller om den slutar att fungerar VARNING Explosionsrisk på grund av att avdrags säkerhetsclip saknas Oskyddade elektriska anslutningar utgör en tändkälla i områden med explosionsrisk O Vid kablar med M8 eller M12 kontakter montera alltid medföljande avdrags säkerhetsclip över anslutningskontakten SE UPP Risk för personskador vid montering under tryck och elektrisk spänning Ri...

Page 17: ......

Page 18: ...figuration is depicted on the title page The delivered product may thus vary from that in the illustration Translation of the original operating instructions The original operating instructions were created in the German language R412024085 BAL 001 AC 2017 06 Subject to modifications All rights reserved by AVENTICS GmbH even and especially in cases of proprietary rights applications It may not be ...

Reviews: